$ EZ-EDS Version 3.23.1.20171205 Generated Electronic Data Sheet [File] DescText = "SUMITOMO"; CreateDate = 04-27-2017; CreateTime = 19:00:00; ModDate = 05-09-2017; ModTime = 12:00:00; Revision = 1.1; [Device] VendCode = 373; VendName = "Sumitomo Heavy Industries, Ltd."; ProdType = 2; ProdTypeStr = "AC Drive Device"; ProdCode = 1001; $ MajRev = 1; $ MinRev = 1; $ ProdName = "DF520"; $ Catalog = "SUMITOMO"; $ [Device Classification] Class1 = EtherNetIP; [Params] Param1 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type 4, $ Data Size in bytes "RPI", $ name "microsecond", $ units "", $ help string 1000,10000000,50000, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places [Assembly] Object_Name = "Assembly Object"; Object_Class_Code = 0x04; Assem20 = "Basic Speed Control Output", , , 0x0001, ,, 32,; Assem25 = "Extended Process Control Output", , 6, 0x0001, ,, 48,; Assem70 = "Basic Speed Control Input", , 4, 0x0001, ,, 32,; Assem75 = "Extended Process Control Input", , , 0x0001, ,, 48,; Assem100 = "Drive Request Output", , 2, 0x0001, ,, 16,; Assem101 = "Drive Request Input", , 8, 0x0001, ,, 64,; Assem102 = "Monitor_Request Output", , 12, 0x0001, ,, 96,; Assem103 = "Monitor Response Input", , 436, 0x0001, ,, 3488,; Assem104 = "Coil Request Output", , 11, 0x0001, ,, 88,; Assem105 = "Coil Response Input", , 11, 0x0001, ,, 88,; [Connection Manager] Object_Name = "Connection Manager Object"; Object_Class_Code = 0x06; Connection1 = 0x04010002, $ trigger & transport $ 0-15 = supported transport classes (class 1) $ 16 = cyclic (1 = supported) $ 17 = change of state (0 = unsupported) $ 18 = on demand (0 = not supported) $ 19-23 = reserved (must be zero) $ 24-27 = exclusive owner $ 28-30 = reserved (must be zero) $ 31 = client 0 (don't care for classes 0 and 1) 0x44640405, $ connection parameters $ 0 = O=>T fixed (1 = supported) $ 1 = O=>T variable (0 = not supported) $ 2 = T=>O fixed (1 = supported) $ 3 = T=>O variable (0 = not supported) $ 4-7 = reserved (must be zero) $ 8-11 = O=>T header (4 byte run/idle) $ 12-15 = T=>O header (no header) $ 16-19 = O=>T connection type (point-to-point) $ 20-23 = T=>O connection type (multicast, point-to-point) $ 24-27 = O=>T priority (scheduled) $ 28-31 = T=>O priority (scheduled) Param1,,Assem20, $ O=>T RPI,Size,Format Param1,,Assem70, $ T=>O RPI,Size,Format ,, $ config part 1 (not used) ,, $ config part 2 (not used) "Basic Speed Control", $ connection name "", $ Help string "20 04 24 01 2C 14 2C 46"; Connection2 = 0x04010002, $ trigger & transport $ 0-15 = supported transport classes (class 1) $ 16 = cyclic (1 = supported) $ 17 = change of state (0 = unsupported) $ 18 = on demand (0 = not supported) $ 19-23 = reserved (must be zero) $ 24-27 = exclusive owner $ 28-30 = reserved (must be zero) $ 31 = client 0 (don't care for classes 0 and 1) 0x44640405, $ connection parameters $ 0 = O=>T fixed (1 = supported) $ 1 = O=>T variable (0 = not supported) $ 2 = T=>O fixed (1 = supported) $ 3 = T=>O variable (0 = not supported) $ 4-7 = reserved (must be zero) $ 8-11 = O=>T header (4 byte run/idle) $ 12-15 = T=>O header (no header) $ 16-19 = O=>T connection type (point-to-point) $ 20-23 = T=>O connection type (multicast, point-to-point) $ 24-27 = O=>T priority (scheduled) $ 28-31 = T=>O priority (scheduled) Param1,,Assem25, $ O=>T RPI,Size,Format Param1,,Assem75, $ T=>O RPI,Size,Format ,, $ config part 1 (not used) ,, $ config part 2 (not used) "Extended Process Control", $ connection name "", $ Help string "20 04 24 01 2C 19 2C 4B"; Connection3 = 0x04010002, $ trigger & transport $ 0-15 = supported transport classes (class 1) $ 16 = cyclic (1 = supported) $ 17 = change of state (0 = unsupported) $ 18 = on demand (0 = not supported) $ 19-23 = reserved (must be zero) $ 24-27 = exclusive owner $ 28-30 = reserved (must be zero) $ 31 = client 0 (don't care for classes 0 and 1) 0x44640405, $ connection parameters $ 0 = O=>T fixed (1 = supported) $ 1 = O=>T variable (0 = not supported) $ 2 = T=>O fixed (1 = supported) $ 3 = T=>O variable (0 = not supported) $ 4-7 = reserved (must be zero) $ 8-11 = O=>T header (4 byte run/idle) $ 12-15 = T=>O header (no header) $ 16-19 = O=>T connection type (point-to-point) $ 20-23 = T=>O connection type (multicast, point-to-point) $ 24-27 = O=>T priority (scheduled) $ 28-31 = T=>O priority (scheduled) Param1,,Assem100, $ O=>T RPI,Size,Format Param1,,Assem101, $ T=>O RPI,Size,Format ,, $ config part 1 (not used) ,, $ config part 2 (not used) "Drive Request", $ connection name "", $ Help string "20 04 24 01 2C 64 2C 65"; Connection4 = 0x04010002, $ trigger & transport $ 0-15 = supported transport classes (class 1) $ 16 = cyclic (1 = supported) $ 17 = change of state (0 = unsupported) $ 18 = on demand (0 = not supported) $ 19-23 = reserved (must be zero) $ 24-27 = exclusive owner $ 28-30 = reserved (must be zero) $ 31 = client 0 (don't care for classes 0 and 1) 0x44640405, $ connection parameters $ 0 = O=>T fixed (1 = supported) $ 1 = O=>T variable (0 = not supported) $ 2 = T=>O fixed (1 = supported) $ 3 = T=>O variable (0 = not supported) $ 4-7 = reserved (must be zero) $ 8-11 = O=>T header (4 byte run/idle) $ 12-15 = T=>O header (no header) $ 16-19 = O=>T connection type (point-to-point) $ 20-23 = T=>O connection type (multicast, point-to-point) $ 24-27 = O=>T priority (scheduled) $ 28-31 = T=>O priority (scheduled) Param1,,Assem102, $ O=>T RPI,Size,Format Param1,,Assem103, $ T=>O RPI,Size,Format ,, $ config part 1 (not used) ,, $ config part 2 (not used) "Monitor_Request", $ connection name "", $ Help string "20 04 24 01 2C 66 2C 67"; Connection5 = 0x04010002, $ trigger & transport $ 0-15 = supported transport classes (class 1) $ 16 = cyclic (1 = supported) $ 17 = change of state (0 = unsupported) $ 18 = on demand (0 = not supported) $ 19-23 = reserved (must be zero) $ 24-27 = exclusive owner $ 28-30 = reserved (must be zero) $ 31 = client 0 (don't care for classes 0 and 1) 0x44640405, $ connection parameters $ 0 = O=>T fixed (1 = supported) $ 1 = O=>T variable (0 = not supported) $ 2 = T=>O fixed (1 = supported) $ 3 = T=>O variable (0 = not supported) $ 4-7 = reserved (must be zero) $ 8-11 = O=>T header (4 byte run/idle) $ 12-15 = T=>O header (no header) $ 16-19 = O=>T connection type (point-to-point) $ 20-23 = T=>O connection type (multicast, point-to-point) $ 24-27 = O=>T priority (scheduled) $ 28-31 = T=>O priority (scheduled) Param1,,Assem104, $ O=>T RPI,Size,Format Param1,,Assem105, $ T=>O RPI,Size,Format ,, $ config part 1 (not used) ,, $ config part 2 (not used) "Coil Request", $ connection name "", $ Help string "20 04 24 01 2C 68 2C 69"; [Port] Object_Name = "Port Object"; Object_Class_Code = 0xF4; Port1 = TCP, "Ethernet Port", "20 F5 24 01", 2, 0, ; [DLR Class] Revision = 3; Object_Name = "Device Level Ring Object"; Object_Class_Code = 0x47; MaxInst = 1; Number_Of_Static_Instances = 1; Class_Attributes = 1, 2, 3; Instance_Attributes = 1, 2, 10, 12; Class_Services = 0x0E; Instance_Services = 0x01, 0x0E; [TCP/IP Interface Class] $ Class Code: 0x00F5 Revision = 4; Object_Name = "TCP/IP Interface Object"; Object_Class_Code = 0xF5; MaxInst = 1; Number_Of_Static_Instances = 1; Max_Number_Of_Dynamic_Instances = 0; Class_Attributes = 1, 2, 3; Instance_Attributes = 1, 2, 3, 4, 5, 6, 10, 11, 13; Class_Services = 0x0E; Instance_Services = 0x01, 0x0E, 0x10; [Ethernet Link Class] Revision = 4; Object_Name = "Ethernet Link Object"; Object_Class_Code = 0xF6; MaxInst = 2; Number_Of_Static_Instances = 2; Max_Number_Of_Dynamic_Instances = 0; Class_Attributes = 1, 2, 3; Instance_Attributes = 1, 2, 3, 4, 5, 6, 10, 11; Class_Services = 0x0E; Instance_Services = 0x01, 0x0E, 0x10, 0x4C; InterfaceLabel1 = "EthernetIP_IF0"; InterfaceLabel2 = "EthernetIP_IF1"; InterfaceType1 = 2; InterfaceType2 = 2; [Motor Data Class] Revision = 1; Object_Name = "Motor Data Object"; Object_Class_Code = 0x28; MaxInst = 1; Number_Of_Static_Instances = 1; Class_Attributes = 1, 2, 3; Instance_Attributes = 3, 6, 7; Class_Services = 0x0E; Instance_Services = 0x0E, 0x10; [Control Supervisor Class] Revision = 1; Object_Name = "Control Supervisor Object"; Object_Class_Code = 0x29; MaxInst = 1; Number_Of_Static_Instances = 1; Instance_Attributes = 3, 4, 5, 7, 8, 10, 11, 12, 15; Instance_Services = 0x05, 0x0E, 0x10; [AC/DC Drive Class] Revision = 1; Object_Name = "AC/DC Drive Object"; Object_Class_Code = 0x2A; MaxInst = 1; Number_Of_Static_Instances = 1; Instance_Attributes = 4, 6, 7, 8, 18, 19, 20, 21; Instance_Services = 0x0E, 0x10; [QoS Class] Revision = 1; Object_Name = "QoS Object"; Object_Class_Code = 0x48; MaxInst = 1; Number_Of_Static_Instances = 1; Class_Attributes = 1, 2, 3; Instance_Attributes = 4, 5, 6, 7, 8; Class_Services = 0x0E; Instance_Services = 0x0E, 0x10;