Ductwork is a crucial component of any home's heating, ventilation, and air conditioning (HVAC) system. It serves as the respiratory system of your house, ensuring that warm or cool air circulates efficiently to maintain comfort throughout the year. One of the most common problems with HVAC systems is HVAC repair services so your HVAC system operates at peak efficiency.. However, like any other part of a home, ductwork can experience issues over time that may require professional repair. Recognizing these signs early can prevent more significant problems and costly repairs down the road.


One of the most common signs that your ductwork needs attention is inconsistent temperature distribution across various rooms in your home. If you notice some rooms are significantly warmer or cooler than others despite having the same thermostat setting, it might indicate a problem with your ducts. This inconsistency often arises from leaks, blockages, or poor design in the duct system that hinders proper airflow.


Another telltale sign of ductwork issues is an increase in energy bills without a corresponding increase in usage. When there are leaks or obstructions in your ducts, your HVAC system has to work harder to maintain the desired temperature, which can lead to increased energy consumption and higher utility costs. Regularly monitoring your energy bills for unexplained spikes can help identify potential ductwork problems early.


Homeowners should also be on the lookout for unusual sounds emanating from their HVAC systems. Noises such as rattling, whistling, or banging could indicate loose or damaged ducts. Over time, connections between sections of ductwork can weaken due to wear and tear or improper installation, leading to gaps where air can escape or enter unwanted areas.


Dust accumulation is another important indicator of possible duct issues. If you notice excessive dust settling on furniture shortly after cleaning or find dust collecting around vents and registers more quickly than usual, it may suggest that there are leaks in your duct system allowing unfiltered air to circulate into living spaces. This not only reduces indoor air quality but also puts additional strain on your HVAC system's filters.


Lastly, if anyone in the household experiences unexplained respiratory issues such as allergies or asthma symptoms worsening indoors, it might signal problems with the ductwork. Leaks and gaps allow contaminants like mold spores and pollen into the airflow within the house which could exacerbate health problems for sensitive individuals.


In conclusion, being aware of these common signs-temperature inconsistencies across rooms; unexpected increases in energy bills; unusual noises from HVAC systems; excessive dust accumulation; and inexplicable health symptoms-can alert homeowners to potential ductwork issues needing professional repair. Addressing these concerns promptly by consulting with an experienced technician will ensure efficient operation of their home's HVAC system while maintaining a comfortable living environment year-round.

Annual HVAC maintenance plays a crucial role in ensuring the efficiency and longevity of your heating, ventilation, and air conditioning system. One often overlooked aspect of this maintenance is the opportunity it provides to identify ductwork problems early. Ductwork, while hidden behind walls and ceilings, is a critical component of your HVAC system, responsible for distributing conditioned air throughout your home. When issues arise within the ducting system, they can lead to a host of problems including reduced efficiency, increased energy bills, and compromised indoor air quality.


One of the first signs that your ductwork may need professional repair is inconsistent temperatures throughout your home. If certain rooms are significantly warmer or cooler than others despite adjusting the thermostat, it could indicate leaks or blockages in the ducts. During annual maintenance checks, technicians can pinpoint these discrepancies using specialized tools to measure airflow and temperature differences across different areas of your home.


Another indicator of ductwork issues is an unexpected increase in energy bills. Leaks in the ducts cause conditioned air to escape into unconditioned spaces like attics or crawlspaces instead of being delivered efficiently to living areas. This forces your HVAC system to work harder to maintain desired temperatures, leading to higher energy consumption. Regular maintenance allows technicians to inspect for signs of wear and tear or damage that could be causing these leaks.


Poor indoor air quality is another red flag indicating potential ductwork problems. Dust accumulation around vents or mold growth inside ducts can exacerbate allergies and respiratory issues for occupants. During an annual check-up, professionals can clean and sanitize ducts as needed and identify any structural issues contributing to contamination such as holes or gaps allowing pollutants from outside or other spaces within the building.


Noise coming from the ductwork when the HVAC system is operating can also signal underlying problems that require attention. Whistling sounds may indicate air escaping through small gaps or cracks whereas rattling could suggest loose connections or components within the duct system itself.


In conclusion, regular annual HVAC maintenance serves as a vital checkpoint for identifying early signs of ductwork problems before they escalate into more serious issues requiring costly repairs or replacements. By addressing these concerns promptly with professional help during routine inspections - whether it's sealing leaks, cleaning contaminants out from within ducts themselves - homeowners can enjoy improved comfort levels while simultaneously enhancing energy efficiency across their entire property all year round without interruption!

How unusual noises and airflow inconsistencies indicate possible ductwork damage

In the intricate tapestry of home maintenance, ductwork often remains an unseen but crucial component, silently ensuring our living spaces remain comfortable and well-ventilated. However, like any system subject to daily wear and tear, ductwork can falter. Among the telltale signs that something is amiss are unusual noises and airflow inconsistencies-subtle indicators that professional repair may be necessary.


Imagine settling into your favorite armchair after a long day, only to be startled by peculiar sounds emanating from within your walls or ceiling. These uncommon noises can range from rattling and whistling to banging or popping, each potentially signaling a different issue within the ductwork. Rattling might suggest loose parts or unfastened segments of ductwork vibrating against each other as air rushes through. Whistling could indicate gaps or leaks where air is escaping instead of being directed properly throughout your home. Banging noises might occur when ducts expand and contract with temperature changes, hinting at insufficient insulation or support.


Airflow inconsistencies present another red flag for potential ductwork damage. If you notice certain rooms in your home are consistently warmer or cooler than others despite thermostat settings, this could point to blockages, leaks, or poorly designed systems causing uneven distribution of conditioned air.

Signs That Your Ductwork Needs Professional Repair - air handler maintenance

  1. condenser unit repair
  2. blower fan replacement
  3. indoor air quality
Such disparities not only affect comfort but also compel HVAC systems to work harder than necessary, leading to increased energy consumption and higher utility bills.


These symptoms should not be ignored as they can exacerbate over time if left unaddressed. Leaks in ducts allow conditioned air to escape into unused spaces such as attics or crawlspaces rather than reaching intended areas. This inefficiency not only diminishes indoor comfort but also strains heating and cooling systems, resulting in premature wear and costly repairs down the line.


Professional intervention becomes imperative when these signs manifest. Trained technicians possess the expertise to diagnose issues accurately and implement effective solutions that restore optimal functionality to your ductwork system. They can pinpoint sources of noise through detailed inspections and employ techniques such as sealing leaks with specialized materials or realigning misaligned sections.


Moreover, regular maintenance conducted by professionals ensures that problems are identified early before escalating into significant concerns requiring extensive repairs or replacements. By addressing minor issues promptly-such as tightening loose connections or cleaning debris buildup-you safeguard both the longevity of your HVAC system and its efficiency in maintaining consistent indoor climates year-round.


In conclusion, unusual noises coupled with airflow inconsistencies serve as vital indicators alerting homeowners about possible damage within their ductwork systems-a call for professional attention rather than mere inconveniences easily dismissed without consequence. Recognizing these signs allows timely interventions aimed at restoring harmony between various elements comprising our homes' environments while ultimately safeguarding investments made towards achieving domestic comfort amidst evolving climatic demands outside our doors.

How unusual noises and airflow inconsistencies indicate possible ductwork damage

The significance of increased energy bills as a sign of inefficient ductwork

In the realm of home maintenance, few issues are as covert yet impactful as inefficient ductwork. Often tucked away behind walls and ceilings, these networks of tunnels silently perform the critical task of distributing conditioned air throughout our homes. However, when they falter, one of the most telling signs is an unwelcome rise in energy bills.


At first glance, a spike in energy costs might be attributed to seasonal changes or fluctuations in utility rates. Yet, when these increases become persistent and inexplicably steep, it's time to consider the health of your ductwork. The connection between rising energy expenses and duct efficiency lies primarily in how well these systems can deliver air from your heating or cooling units to various parts of your home without loss.


Inefficient ductwork can lead to significant energy waste through leaks, poor insulation, or blockages. When ducts are compromised by gaps or leaks-often due to age or improper installation-the conditioned air escapes before reaching its intended destination. This means that your HVAC system has to work harder and longer to maintain desired temperatures within your living spaces, consequently driving up energy usage and costs.


Moreover, poorly insulated ducts can result in temperature losses as air travels through unconditioned spaces like attics or basements. If ducts run through regions that are not climate-controlled, inadequate insulation allows heat transfer between the ducts and their surroundings. In winter months, warm air loses heat en route to its final destination; conversely, during summer months, cooled air absorbs ambient heat along its journey.


Blockages present another culprit for increased energy consumption.

Signs That Your Ductwork Needs Professional Repair - smart thermostat installation

  1. airflow balancing
  2. commercial HVAC services
  3. HVAC installation
Accumulations of dust and debris can significantly obstruct airflow within the ductwork system. Not only does this strain your HVAC unit by forcing it to push harder against resistance but also hinders even distribution of temperature across rooms-prompting frequent thermostat adjustments that further escalate energy use.


The financial implications extend beyond just monthly utility bills; inefficient ductwork accelerates wear and tear on HVAC systems due to overexertion. This often leads to costly repairs or even premature replacement-a burden no homeowner desires.


Recognizing increased energy bills as a signal for potential duct issues prompts timely investigation and intervention by professionals who can assess and rectify inefficiencies. Sealing leaks with appropriate materials ensures minimal air escape while upgrading insulation helps maintain consistent temperatures through transit zones that previously led to loss.


Regular maintenance checks by certified experts will identify obstructions early on before they morph into larger problems requiring substantial repairs-or worse yet-a complete overhaul of your system components.


Ultimately, viewing heightened energy bills as more than just financial nuisances allows homeowners insight into hidden inefficiencies lurking within their property's infrastructure-and empowers them towards proactive solutions that safeguard both comfort levels indoors and fiscal health alike.

Indoor air quality concerns linked to compromised or leaky ducts

Indoor air quality is an essential component of a healthy living environment, yet it often goes unnoticed until issues arise. One significant contributor to poor indoor air quality is compromised or leaky ductwork. Understanding the signs that your ductwork needs professional repair can help you maintain a healthier home and prevent long-term health concerns.


Ductwork serves as the circulatory system of your home's heating and cooling operations, distributing conditioned air throughout each room. When this system is compromised, either through leaks or other forms of damage, it can have a dramatic impact on the quality of the air you breathe indoors. Leaky ducts can introduce various pollutants into your home, including dust, mold spores, and chemical irritants from household cleaning products stored in attics or basements where ductwork often runs. This influx of contaminants not only affects those with allergies and respiratory conditions but also poses risks to generally healthy individuals.


One clear sign that your ductwork may need professional attention is a noticeable decrease in air quality. If you've observed more dust settling on surfaces shortly after cleaning or experienced unusual odors circulating through your home, these could be indications that outside contaminants are entering your airflow through compromised ducts. Similarly, if household members begin to experience increased allergy symptoms or respiratory issues without any obvious environmental cause, it may be time to inspect your duct system for leaks.


Another indicator of problematic ductwork is uneven heating or cooling across different rooms in your home. Leaks allow conditioned air to escape before reaching its intended destination, leading to inconsistent temperatures between spaces. You might find yourself frequently adjusting thermostats in an attempt to achieve comfort levels that were once easily maintained-a clear sign that energy efficiency has been compromised due to faulty ducts.


Moreover, an unexpected increase in utility bills can signal underlying issues with your HVAC system's efficiency caused by leaky ductwork. When conditioned air escapes through gaps or holes in the ducts rather than reaching living spaces as intended, your HVAC system must work harder and longer cycles to maintain desired temperatures. This strain not only elevates energy costs but also accelerates wear and tear on equipment, potentially leading to more frequent repairs or even premature replacement.


In conclusion, while indoor air quality concerns linked to leaky or compromised ducts might not always be immediately apparent, their effects can significantly impact both health and comfort within the home.

Signs That Your Ductwork Needs Professional Repair - air handler maintenance

  1. smart thermostat installation
  2. residential HVAC systems
  3. air handler maintenance
Recognizing signs like reduced air quality, inconsistent temperatures between rooms, and rising energy bills can help homeowners identify when professional repair services are necessary. By addressing these issues promptly with expert assistance, you ensure a safer living environment while protecting both financial investments in HVAC systems and overall well-being for all household members.

Indoor air quality concerns linked to compromised or leaky ducts
When to seek professional repair services for ductwork issues during routine maintenance
When to seek professional repair services for ductwork issues during routine maintenance

During routine maintenance of your HVAC system, it's crucial to pay close attention to the ductwork, as it plays a pivotal role in ensuring efficient airflow and maintaining indoor air quality. While some minor issues can be addressed with basic DIY skills, there are certain signs that unmistakably signal the need for professional repair services.


One of the primary indicators that your ductwork requires professional attention is inconsistent temperatures throughout your home. If you notice that some rooms are significantly warmer or cooler than others, this could suggest leaks or blockages within the ducts. These inconsistencies not only compromise comfort but also lead to increased energy bills, as your HVAC system works harder to maintain desired temperatures.


Another sign is unusual noises emanating from the ductwork. While a gentle hum is normal when the system is running, rattles, whistles, or banging sounds indicate potential problems such as loose connections or debris lodged within the ducts. Such issues can exacerbate over time if not addressed by a trained technician.


Visible signs of damage such as rust, dents, or disconnected sections are clear indicators that professional intervention is necessary. Physical damage can severely impair the efficiency of your HVAC system and might even pose safety hazards if left unattended. Technicians have the expertise to assess and rectify these issues safely and effectively.


Dust accumulation and poor air quality are also red flags for ductwork problems. Excessive dust around vents and rapidly accumulating dust on surfaces often point to leaks in the duct system allowing contaminants to bypass filters. Furthermore, if household members experience unexplained allergies or respiratory issues, it may be due to pollutants circulating through compromised ducts.


Lastly, an increase in energy bills without a corresponding increase in usage signals inefficiencies potentially rooted in faulty ductwork. Leaks and blockages force your HVAC system to consume more energy than necessary, leading to higher costs over time.


In conclusion, while routine maintenance helps identify early signs of ductwork issues, recognizing when these signs necessitate professional repair is essential for maintaining an efficient and safe home environment. Inconsistent temperatures, unusual noises, visible damage, declining air quality, and rising energy costs all warrant expert evaluation and repair to ensure optimal performance of your HVAC system and overall comfort in your living space.

 

An air filter being cleaned

Indoor air quality (IAQ) is the air quality within buildings and structures. Poor indoor air quality due to indoor air pollution is known to affect the health, comfort, and well-being of building occupants. It has also been linked to sick building syndrome, respiratory issues, reduced productivity, and impaired learning in schools. Common pollutants of indoor air include: secondhand tobacco smoke, air pollutants from indoor combustion, radon, molds and other allergens, carbon monoxide, volatile organic compounds, legionella and other bacteria, asbestos fibers, carbon dioxide,[1] ozone and particulates.

Source control, filtration, and the use of ventilation to dilute contaminants are the primary methods for improving indoor air quality. Although ventilation is an integral component of maintaining good indoor air quality, it may not be satisfactory alone.[2] In scenarios where outdoor pollution would deteriorate indoor air quality, other treatment devices such as filtration may also be necessary.[3]

IAQ is evaluated through collection of air samples, monitoring human exposure to pollutants, analysis of building surfaces, and computer modeling of air flow inside buildings. IAQ is part of indoor environmental quality (IEQ), along with other factors that exert an influence on physical and psychological aspects of life indoors (e.g., lighting, visual quality, acoustics, and thermal comfort).[4]

Indoor air pollution is a major health hazard in developing countries and is commonly referred to as "household air pollution" in that context.[5] It is mostly relating to cooking and heating methods by burning biomass fuel, in the form of wood, charcoal, dung, and crop residue, in indoor environments that lack proper ventilation. Millions of people, primarily women and children, face serious health risks. In total, about three billion people in developing countries are affected by this problem. The World Health Organization (WHO) estimates that cooking-related indoor air pollution causes 3.8 million annual deaths.[6] The Global Burden of Disease study estimated the number of deaths in 2017 at 1.6 million.[7]

Definition

[edit]

For health reasons it is crucial to breathe clean air, free from chemicals and toxicants as much as possible. It is estimated that humans spend approximately 90% of their lifetime indoors[8] and that indoor air pollution in some places can be much worse than that of the ambient air.[9][10]

Various factors contribute to high concentrations of pollutants indoors, ranging from influx of pollutants from external sources, off-gassing by furniture, furnishings including carpets, indoor activities (cooking, cleaning, painting, smoking, etc. in homes to using office equipment in offices), thermal comfort parameters such as temperature, humidity, airflow and physio-chemical properties of the indoor air.[citation needed] Air pollutants can enter a building in many ways, including through open doors or windows. Poorly maintained air conditioners/ventilation systems can harbor mold, bacteria, and other contaminants, which are then circulated throughout indoor spaces, contributing to respiratory problems and allergies.

There have been many debates among indoor air quality specialists about the proper definition of indoor air quality and specifically what constitutes "acceptable" indoor air quality.

Health effects

[edit]
Share of deaths from indoor air pollution. Darker colors mean higher numbers.

IAQ is significant for human health as humans spend a large proportion of their time in indoor environments. Americans and Europeans on average spend approximately 90% of their time indoors.[11][12]

The World Health Organization (WHO) estimates that 3.2 million people die prematurely every year from illnesses attributed to indoor air pollution caused by indoor cooking, with over 237 thousand of these being children under 5. These include around an eighth of all global ischaemic heart disease, stroke, and lung cancer deaths. Overall the WHO estimated that poor indoor air quality resulted in the loss of 86 million healthy life years in 2019.[13]

Studies in the UK and Europe show exposure to indoor air pollutants, chemicals and biological contamination can irritate the upper airway system, trigger or exacerbate asthma and other respiratory or cardiovascular conditions, and may even have carcinogenic effects.[14][15][16][17][18][19]

Poor indoor air quality can cause sick building syndrome. Symptoms include burning of the eyes, scratchy throat, blocked nose, and headaches.[20]

Common pollutants

[edit]

Generated by indoor combustion

[edit]
a 3-stone stove
A traditional wood-fired 3-stone stove in Guatemala, which causes indoor air pollution

Indoor combustion, such as for cooking or heating, is a major cause of indoor air pollution and causes significant health harms and premature deaths. Hydrocarbon fires cause air pollution. Pollution is caused by both biomass and fossil fuels of various types, but some forms of fuels are more harmful than others.

Indoor fire can produce black carbon particles, nitrogen oxides, sulfur oxides, and mercury compounds, among other emissions.[21] Around 3 billion people cook over open fires or on rudimentary cook stoves. Cooking fuels are coal, wood, animal dung, and crop residues.[22] IAQ is a particular concern in low and middle-income countries where such practices are common.[23]

Cooking using natural gas (also called fossil gas, methane gas or simply gas) is associated with poorer indoor air quality. Combustion of gas produces nitrogen dioxide and carbon monixide, and can lead to increased concentrations of nitrogen dioxide throughout the home environment which is linked to respiratory issues and diseases.[24][25]

Carbon monoxide

[edit]

One of the most acutely toxic indoor air contaminants is carbon monoxide (CO), a colourless and odourless gas that is a by-product of incomplete combustion. Carbon monoxide may be emitted from tobacco smoke and generated from malfunctioning fuel burning stoves (wood, kerosene, natural gas, propane) and fuel burning heating systems (wood, oil, natural gas) and from blocked flues connected to these appliances.[26] In developed countries the main sources of indoor CO emission come from cooking and heating devices that burn fossil fuels and are faulty, incorrectly installed or poorly maintained.[27] Appliance malfunction may be due to faulty installation or lack of maintenance and proper use.[26] In low- and middle-income countries the most common sources of CO in homes are burning biomass fuels and cigarette smoke.[27]

Health effects of CO poisoning may be acute or chronic and can occur unintentionally or intentionally (self-harm). By depriving the brain of oxygen, acute exposure to carbon monoxide may have effects on the neurological system (headache, nausea, dizziness, alteration in consciousness and subjective weakness), the cardiovascular and respiratory systems (myocardial infarction, shortness of breath, or rapid breathing, respiratory failure). Acute exposure can also lead to long-term neurological effects such as cognitive and behavioural changes. Severe CO poisoning may lead to unconsciousness, coma and death. Chronic exposure to low concentrations of carbon monoxide may lead to lethargy, headaches, nausea, flu-like symptoms and neuropsychological and cardiovascular issues.[28][26]

The WHO recommended levels of indoor CO exposure in 24 hours is 4 mg/m3.[29] Acute exposure should not exceed 10 mg/m3 in 8 hours, 35 mg/m3 in one hour and 100 mg/m3 in 15 minutes.[27]

Secondhand tobacco smoke

[edit]

Secondhand smoke is tobacco smoke which affects people other than the 'active' smoker. It is made up of the exhaled smoke (15%) and mostly of smoke coming from the burning end of the cigarette, known as sidestream smoke (85%).[30]

Secondhand smoke contains more than 7000 chemicals, of which hundreds are harmful to health.[30] Secondhand tobacco smoke includes both a gaseous and a particulate materials which, with particular hazards arising from levels of carbon monoxide and very small particulates (fine particulate matter, especially PM2.5 and PM10) which get into the bronchioles and alveoles in the lung.[31] Inhaling secondhand smoke on multiple occasions can cause asthma, pneumonia, lung cancer, and sudden infant death syndrome, among other conditions.[32]

Thirdhand smoke (THS) refers to chemicals that settle on objects and bodies indoors after smoking. Exposure to thirdhand smoke can happen even after the actual cigarette smoke is not present anymore and affect those entering the indoor environment much later. Toxic substances of THS can react with other chemicals in the air and produce new toxic chemicals that are otherwise not present in cigarettes.[33]

The only certain method to improve indoor air quality as regards secondhand smoke is to eliminate smoking indoors.[34] Indoor e-cigarette use also increases home particulate matter concentrations.[35]

Particulates

[edit]

Atmospheric particulate matter, also known as particulates, can be found indoors and can affect the health of occupants. Indoor particulate matter can come from different indoor sources or be created as secondary aerosols through indoor gas-to-particle reactions. They can also be outdoor particles that enter indoors. These indoor particles vary widely in size, ranging from nanomet (nanoparticles/ultrafine particles emitted from combustion sources) to micromet (resuspensed dust).[36] Particulate matter can also be produced through cooking activities. Frying produces higher concentrations than boiling or grilling and cooking meat produces higher concentrations than cooking vegetables.[37] Preparing a Thanksgiving dinner can produce very high concentrations of particulate matter, exceeding 300 μg/m3.[38]

Particulates can penetrate deep into the lungs and brain from blood streams, causing health problems such as heart disease, lung disease, cancer and preterm birth.[39]

Generated from building materials, furnishing and consumer products

[edit]

Volatile organic compounds

[edit]

Volatile organic compounds (VOCs) include a variety of chemicals, some of which may have short- and long-term adverse health effects. There are numerous sources of VOCs indoors, which means that their concentrations are consistently higher indoors (up to ten times higher) than outdoors.[40] Some VOCs are emitted directly indoors, and some are formed through the subsequent chemical reactions that can occur in the gas-phase, or on surfaces.[41][42] VOCs presenting health hazards include benzene, formaldehyde, tetrachloroethylene and trichloroethylene.[43]

VOCs are emitted by thousands of indoor products. Examples include: paints, varnishes, waxes and lacquers, paint strippers, cleaning and personal care products, pesticides, building materials and furnishings, office equipment such as copiers and printers, correction fluids and carbonless copy paper, graphics and craft materials including glues and adhesives, permanent markers, and photographic solutions.[44] Chlorinated drinking water releases chloroform when hot water is used in the home. Benzene is emitted from fuel stored in attached garages.

Human activities such as cooking and cleaning can also emit VOCs.[45][46] Cooking can release long-chain aldehydes and alkanes when oil is heated and terpenes can be released when spices are prepared and/or cooked.[45] Leaks of natural gas from cooking appliances have been linked to elevated levels of VOCs including benzene in homes in the USA.[47] Cleaning products contain a range of VOCs, including monoterpenes, sesquiterpenes, alcohols and esters. Once released into the air, VOCs can undergo reactions with ozone and hydroxyl radicals to produce other VOCs, such as formaldehyde.[46]

Health effects include eye, nose, and throat irritation; headaches, loss of coordination, nausea; and damage to the liver, kidney, and central nervous system.[48]

Testing emissions from building materials used indoors has become increasingly common for floor coverings, paints, and many other important indoor building materials and finishes.[49] Indoor materials such as gypsum boards or carpet act as VOC 'sinks', by trapping VOC vapors for extended periods of time, and releasing them by outgassing. The VOCs can also undergo transformation at the surface through interaction with ozone.[42] In both cases, these delayed emissions can result in chronic and low-level exposures to VOCs.[50]

Several initiatives aim to reduce indoor air contamination by limiting VOC emissions from products. There are regulations in France and in Germany, and numerous voluntary ecolabels and rating systems containing low VOC emissions criteria such as EMICODE,[51] M1,[52] Blue Angel[53] and Indoor Air Comfort[54] in Europe, as well as California Standard CDPH Section 01350[55] and several others in the US. Due to these initiatives an increasing number of low-emitting products became available to purchase.

At least 18 microbial VOCs (MVOCs) have been characterised[56][57] including 1-octen-3-ol (mushroom alcohol), 3-Methylfuran, 2-pentanol, 2-hexanone, 2-heptanone, 3-octanone, 3-octanol, 2-octen-1-ol, 1-octene, 2-pentanone, 2-nonanone, borneol, geosmin, 1-butanol, 3-methyl-1-butanol, 3-methyl-2-butanol, and thujopsene. The last four are products of Stachybotrys chartarum, which has been linked with sick building syndrome.[56]

Asbestos fibers

[edit]

Many common building materials used before 1975 contain asbestos, such as some floor tiles, ceiling tiles, shingles, fireproofing, heating systems, pipe wrap, taping muds, mastics, and other insulation materials. Normally, significant releases of asbestos fiber do not occur unless the building materials are disturbed, such as by cutting, sanding, drilling, or building remodelling. Removal of asbestos-containing materials is not always optimal because the fibers can be spread into the air during the removal process. A management program for intact asbestos-containing materials is often recommended instead.

When asbestos-containing material is damaged or disintegrates, microscopic fibers are dispersed into the air. Inhalation of asbestos fibers over long exposure times is associated with increased incidence of lung cancer, mesothelioma, and asbestosis. The risk of lung cancer from inhaling asbestos fibers is significantly greater for smokers. The symptoms of disease do not usually appear until about 20 to 30 years after the first exposure to asbestos.

Although all asbestos is hazardous, products that are friable, e.g. sprayed coatings and insulation, pose a significantly higher hazard as they are more likely to release fibers to the air.[58]

Microplastics

[edit]

Microplastic is a type of airborne particulates and is found to prevail in air.[59][60][61][62] A 2017 study found indoor airborne microfiber concentrations between 1.0 and 60.0 microfibers per cubic meter (33% of which were found to be microplastics).[63] Airborne microplastic dust can be produced during renovation, building, bridge and road reconstruction projects[64] and the use of power tools.[65]

Ozone

[edit]

Indoors ozone (O3) is produced by certain high-voltage electric devices (such as air ionizers), and as a by-product of other types of pollution. It appears in lower concentrations indoors than outdoors, usually at 0.2-0.7 of the outdoor concentration.[66] Typically, most ozone is lost to surface reactions indoors, rather than to reactions in air, due to the large surface to volume ratios found indoors.[67]

Outdoor air used for ventilation may have sufficient ozone to react with common indoor pollutants as well as skin oils and other common indoor air chemicals or surfaces. Particular concern is warranted when using "green" cleaning products based on citrus or terpene extracts, because these chemicals react very quickly with ozone to form toxic and irritating chemicals[46] as well as fine and ultrafine particles.[68] Ventilation with outdoor air containing elevated ozone concentrations may complicate remediation attempts.[69]

The WHO standard for ozone concentration is 60 μg/m3 for long-term exposure and 100 μg/m3 as the maximum average over an 8-hour period.[29] The EPA standard for ozone concentration is 0.07 ppm average over an 8-hour period.[70]

Biological agents

[edit]

Mold and other allergens

[edit]

Occupants in buildings can be exposed to fungal spores, cell fragments, or mycotoxins which can arise from a host of means, but there are two common classes: (a) excess moisture induced growth of mold colonies and (b) natural substances released into the air such as animal dander and plant pollen.[71]

While mold growth is associated with high moisture levels,[72] it is likely to grow when a combination of favorable conditions arises. As well as high moisture levels, these conditions include suitable temperatures, pH and nutrient sources.[73] Mold grows primarily on surfaces, and it reproduces by releasing spores, which can travel and settle in different locations. When these spores experience appropriate conditions, they can germinate and lead to mycelium growth.[74] Different mold species favor different environmental conditions to germinate and grow, some being more hydrophilic (growing at higher levels of relative humidity) and other more xerophilic (growing at levels of relative humidity as low as 75–80%).[74][75]

Mold growth can be inhibited by keeping surfaces at conditions that are further from condensation, with relative humidity levels below 75%. This usually translates to a relative humidity of indoor air below 60%, in agreement with the guidelines for thermal comfort that recommend a relative humidity between 40 and 60 %. Moisture buildup in buildings may arise from water penetrating areas of the building envelope or fabric, from plumbing leaks, rainwater or groundwater penetration, or from condensation due to improper ventilation, insufficient heating or poor thermal quality of the building envelope.[76] Even something as simple as drying clothes indoors on radiators can increase the risk of mold growth, if the humidity produced is not able to escape the building via ventilation.[77]

Mold predominantly affects the airways and lungs. Known effects of mold on health include asthma development and exacerbation,[78] with children and elderly at greater risk of more severe health impacts.[79] Infants in homes with mold have a much greater risk of developing asthma and allergic rhinitis.[80][71] More than half of adult workers in moldy or humid buildings suffer from nasal or sinus symptoms due to mold exposure.[71] Some varieties of mold contain toxic compounds (mycotoxins). However, exposure to hazardous levels of mycotoxin via inhalation is not possible in most cases, as toxins are produced by the fungal body and are not at significant levels in the released spores.

Legionella

[edit]

Legionnaires' disease is caused by a waterborne bacterium Legionella that grows best in slow-moving or still, warm water. The primary route of exposure is through the creation of an aerosol effect, most commonly from evaporative cooling towers or showerheads. A common source of Legionella in commercial buildings is from poorly placed or maintained evaporative cooling towers, which often release water in an aerosol which may enter nearby ventilation intakes. Outbreaks in medical facilities and nursing homes, where patients are immuno-suppressed and immuno-weak, are the most commonly reported cases of Legionellosis. More than one case has involved outdoor fountains at public attractions. The presence of Legionella in commercial building water supplies is highly under-reported, as healthy people require heavy exposure to acquire infection.

Legionella testing typically involves collecting water samples and surface swabs from evaporative cooling basins, shower heads, faucets/taps, and other locations where warm water collects. The samples are then cultured and colony forming units (cfu) of Legionella are quantified as cfu/liter.

Legionella is a parasite of protozoans such as amoeba, and thus requires conditions suitable for both organisms. The bacterium forms a biofilm which is resistant to chemical and antimicrobial treatments, including chlorine. Remediation for Legionella outbreaks in commercial buildings vary, but often include very hot water flushes (160 °F (71 °C)), sterilisation of standing water in evaporative cooling basins, replacement of shower heads, and, in some cases, flushes of heavy metal salts. Preventive measures include adjusting normal hot water levels to allow for 120 °F (49 °C) at the tap, evaluating facility design layout, removing faucet aerators, and periodic testing in suspect areas.

Other bacteria

[edit]
Airborne bacteria

There are many bacteria of health significance found in indoor air and on indoor surfaces. The role of microbes in the indoor environment is increasingly studied using modern gene-based analysis of environmental samples. Currently, efforts are under way to link microbial ecologists and indoor air scientists to forge new methods for analysis and to better interpret the results.[81]

A large fraction of the bacteria found in indoor air and dust are shed from humans. Among the most important bacteria known to occur in indoor air are Mycobacterium tuberculosis, Staphylococcus aureus, Streptococcus pneumoniae.[citation needed]

Virus

[edit]
Ninth floor layout of the Metropole Hotel in Hong Kong, showing where an outbreak of the severe acute respiratory syndrome (SARS) occurred

Viruses can also be a concern for indoor air quality. During the 2002–2004 SARS outbreak, virus-laden aerosols were found to have seeped into bathrooms from the bathroom floor drains, exacerbated by the draw of bathroom exhaust fans, resulting in the rapid spread of SARS in Amoy Gardens in Hong Kong.[82][83] Elsewhere in Hong Kong, SARS CoV RNA was found on the carpet and in the air intake vents of the Metropole Hotel, which showed that secondary environmental contamination could generate infectious aerosols and resulted in superspreading events.[84]

Carbon dioxide

[edit]

Humans are the main indoor source of carbon dioxide (CO2) in most buildings. Indoor CO2 levels are an indicator of the adequacy of outdoor air ventilation relative to indoor occupant density and metabolic activity.

Indoor CO2 levels above 500 ppm can lead to higher blood pressure and heart rate, and increased peripheral blood circulation.[85] With CO2 concentrations above 1000 ppm cognitive performance might be affected, especially when doing complex tasks, making decision making and problem solving slower but not less accurate.[86][87] However, evidence on the health effects of CO2 at lower concentrations is conflicting and it is difficult to link CO2 to health impacts at exposures below 5000 ppm – reported health outcomes may be due to the presence of human bioeffluents, and other indoor air pollutants related to inadequate ventilation.[88]

Indoor carbon dioxide concentrations can be used to evaluate the quality of a room or a building's ventilation.[89] To eliminate most complaints caused by CO2, the total indoor CO2 level should be reduced to a difference of no greater than 700 ppm above outdoor levels.[90] The National Institute for Occupational Safety and Health (NIOSH) considers that indoor air concentrations of carbon dioxide that exceed 1000 ppm are a marker suggesting inadequate ventilation.[91] The UK standards for schools say that carbon dioxide levels of 800 ppm or lower indicate that the room is well-ventilated.[92] Regulations and standards from around the world show that CO2 levels below 1000 ppm represent good IAQ, between 1000 and 1500 ppm represent moderate IAQ and greater than 1500 ppm represent poor IAQ.[88]

Carbon dioxide concentrations in closed or confined rooms can increase to 1,000 ppm within 45 minutes of enclosure. For example, in a 3.5-by-4-metre (11 ft × 13 ft) sized office, atmospheric carbon dioxide increased from 500 ppm to over 1,000 ppm within 45 minutes of ventilation cessation and closure of windows and doors.[93]

Radon

[edit]

Radon is an invisible, radioactive atomic gas that results from the radioactive decay of radium, which may be found in rock formations beneath buildings or in certain building materials themselves.

Radon is probably the most pervasive serious hazard for indoor air in the United States and Europe. It is a major cause of lung cancer, responsible for 3–14% of cases in countries, leading to tens of thousands of deaths.[94]

Radon gas enters buildings as a soil gas. As it is a heavy gas it will tend to accumulate at the lowest level. Radon may also be introduced into a building through drinking water particularly from bathroom showers. Building materials can be a rare source of radon, but little testing is carried out for stone, rock or tile products brought into building sites; radon accumulation is greatest for well insulated homes.[95] There are simple do-it-yourself kits for radon gas testing, but a licensed professional can also check homes.

The half-life for radon is 3.8 days, indicating that once the source is removed, the hazard will be greatly reduced within a few weeks. Radon mitigation methods include sealing concrete slab floors, basement foundations, water drainage systems, or by increasing ventilation.[96] They are usually cost effective and can greatly reduce or even eliminate the contamination and the associated health risks.[citation needed]

Radon is measured in picocuries per liter of air (pCi/L) or becquerel per cubic meter (Bq m-3). Both are measurements of radioactivity. The World Health Organization (WHO) sets the ideal indoor radon levels at 100 Bq/m-3.[97] In the United States, it is recommend to fix homes with radon levels at or above 4 pCi/L. At the same time it is also recommends that people think about fixing their homes for radon levels between 2 pCi/L and 4 pCi/L.[98] In the United Kingdom the ideal is presence of radon indoors is 100 Bq/m-3. Action needs to be taken in homes with 200 Bq/m−3 or more.[99]

Interactive maps of radon affected areas are available for various regions and countries of the world.[100][101][102]

IAQ and climate change

[edit]

Indoor air quality is linked inextricably to outdoor air quality. The Intergovernmental Panel on Climate Change (IPCC) has varying scenarios that predict how the climate will change in the future.[103] Climate change can affect indoor air quality by increasing the level of outdoor air pollutants such as ozone and particulate matter, for example through emissions from wildfires caused by extreme heat and drought.[104][105] Numerous predictions for how indoor air pollutants will change have been made,[106][107][108][109] and models have attempted to predict how the forecasted IPCC scenarios will vary indoor air quality and indoor comfort parameters such as humidity and temperature.[110]

The net-zero challenge requires significant changes in the performance of both new and retrofitted buildings. However, increased energy efficient housing will trap pollutants inside, whether produced indoors or outdoors, and lead to an increase in human exposure.[111][112]

Indoor air quality standards and monitoring

[edit]

Quality guidelines and standards

[edit]

For occupational exposure, there are standards, which cover a wide range of chemicals, and applied to healthy adults who are exposed over time at workplaces (usually industrial environments).These are published by organisations such as Occupational Safety and Health Administration (OSHA), the National Institute for Occupational Safety and Health (NIOSH), the UK Health and Safety Executive (HSE).

There is no consensus globally about indoor air quality standards, or health-based guidelines. However, there are regulations from some individual countries and from health organisations. For example, the World Health Organization (WHO) has published health-based global air quality guidelines for the general population that are applicable both to outdoor and indoor air,[29] as well as the WHO IAQ guidelines for selected compounds,[113] whereas the UK Health Security Agency published IAQ guidelines for selected VOCs.[114] The Scientific and Technical Committee (STC34) of the International Society of Indoor Air Quality and Climate (ISIAQ) created an open database that collects indoor environmental quality guidelines worldwide.[115] The database is focused on indoor air quality (IAQ), but is currently extended to include standards, regulations, and guidelines related to ventilation, comfort, acoustics, and lighting.[116][117]

Real-time monitoring

[edit]

Since indoor air pollutants can adversely affect human health, it is important to have real-time indoor air quality assessment/monitoring system that can help not only in the improvement of indoor air quality but also help in detection of leaks, spills in a work environment and boost energy efficiency of buildings by providing real-time feedback to the heating, ventilation, and air conditioning (HVAC) system(s).[118] Additionally, there have been enough studies that highlight the correlation between poor indoor air quality and loss of performance and productivity of workers in an office setting.[119]  

Combining the Internet of Things (IoT) technology with real-time IAQ monitoring systems has  tremendously gained momentum and popularity as interventions can be done based on the real-time sensor data and thus help in the IAQ improvement.[120]   

Improvement measures

[edit]

Indoor air quality can be addressed, achieved or maintained during the design of new buildings or as mitigating measures in existing buildings. A hierarchy of measures has been proposed by the Institute of Air Quality Management. It emphasises removing pollutant sources, reducing emissions from any remaining sources, disrupting pathways between sources and the people exposed, protecting people from exposure to pollutants, and removing people from areas with poor air quality.[121]

A report assisted by the Institute for Occupational Safety and Health of the German Social Accident Insurance can support in the systematic investigation of individual health problems arising at indoor workplaces, and in the identification of practical solutions.[122]

Source control

[edit]

HVAC design

[edit]

Environmentally sustainable design concepts include aspects of commercial and residential heating, ventilation and air-conditioning (HVAC) technologies. Among several considerations, one of the topics attended to is the issue of indoor air quality throughout the design and construction stages of a building's life.[citation needed]

One technique to reduce energy consumption while maintaining adequate air quality, is demand-controlled ventilation. Instead of setting throughput at a fixed air replacement rate, carbon dioxide sensors are used to control the rate dynamically, based on the emissions of actual building occupants.[citation needed]

One way of quantitatively ensuring the health of indoor air is by the frequency of effective turnover of interior air by replacement with outside air. In the UK, for example, classrooms are required to have 2.5 outdoor air changes per hour. In halls, gym, dining, and physiotherapy spaces, the ventilation should be sufficient to limit carbon dioxide to 1,500 ppm. In the US, ventilation in classrooms is based on the amount of outdoor air per occupant plus the amount of outdoor air per unit of floor area, not air changes per hour. Since carbon dioxide indoors comes from occupants and outdoor air, the adequacy of ventilation per occupant is indicated by the concentration indoors minus the concentration outdoors. The value of 615 ppm above the outdoor concentration indicates approximately 15 cubic feet per minute of outdoor air per adult occupant doing sedentary office work where outdoor air contains over 400 ppm[123] (global average as of 2023). In classrooms, the requirements in the ASHRAE standard 62.1, Ventilation for Acceptable Indoor Air Quality, would typically result in about 3 air changes per hour, depending on the occupant density. As the occupants are not the only source of pollutants, outdoor air ventilation may need to be higher when unusual or strong sources of pollution exist indoors.

When outdoor air is polluted, bringing in more outdoor air can actually worsen the overall quality of the indoor air and exacerbate some occupant symptoms related to outdoor air pollution. Generally, outdoor country air is better than indoor city air.[citation needed]

The use of air filters can trap some of the air pollutants. Portable room air cleaners with HEPA filters can be used if ventilation is poor or outside air has high level of PM 2.5.[122] Air filters are used to reduce the amount of dust that reaches the wet coils.[citation needed] Dust can serve as food to grow molds on the wet coils and ducts and can reduce the efficiency of the coils.[citation needed]

The use of trickle vents on windows is also valuable to maintain constant ventilation. They can help prevent mold and allergen build up in the home or workplace. They can also reduce the spread of some respiratory infections.[124]

Moisture management and humidity control requires operating HVAC systems as designed. Moisture management and humidity control may conflict with efforts to conserve energy. For example, moisture management and humidity control requires systems to be set to supply make-up air at lower temperatures (design levels), instead of the higher temperatures sometimes used to conserve energy in cooling-dominated climate conditions. However, for most of the US and many parts of Europe and Japan, during the majority of hours of the year, outdoor air temperatures are cool enough that the air does not need further cooling to provide thermal comfort indoors.[citation needed] However, high humidity outdoors creates the need for careful attention to humidity levels indoors. High humidity give rise to mold growth and moisture indoors is associated with a higher prevalence of occupant respiratory problems.[citation needed]

The "dew point temperature" is an absolute measure of the moisture in air. Some facilities are being designed with dew points in the lower 50s °F, and some in the upper and lower 40s °F.[citation needed] Some facilities are being designed using desiccant wheels with gas-fired heaters to dry out the wheel enough to get the required dew points.[citation needed] On those systems, after the moisture is removed from the make-up air, a cooling coil is used to lower the temperature to the desired level.[citation needed]

Commercial buildings, and sometimes residential, are often kept under slightly positive air pressure relative to the outdoors to reduce infiltration. Limiting infiltration helps with moisture management and humidity control.

Dilution of indoor pollutants with outdoor air is effective to the extent that outdoor air is free of harmful pollutants. Ozone in outdoor air occurs indoors at reduced concentrations because ozone is highly reactive with many chemicals found indoors. The products of the reactions between ozone and many common indoor pollutants include organic compounds that may be more odorous, irritating, or toxic than those from which they are formed. These products of ozone chemistry include formaldehyde, higher molecular weight aldehydes, acidic aerosols, and fine and ultrafine particles, among others. The higher the outdoor ventilation rate, the higher the indoor ozone concentration and the more likely the reactions will occur, but even at low levels, the reactions will take place. This suggests that ozone should be removed from ventilation air, especially in areas where outdoor ozone levels are frequently high.

Effect of indoor plants

[edit]
Spider plants (Chlorophytum comosum) absorb some airborne contaminants.

Houseplants together with the medium in which they are grown can reduce components of indoor air pollution, particularly volatile organic compounds (VOC) such as benzene, toluene, and xylene. Plants remove CO2 and release oxygen and water, although the quantitative impact for house plants is small. The interest in using potted plants for removing VOCs was sparked by a 1989 NASA study conducted in sealed chambers designed to replicate the environment on space stations. However, these results suffered from poor replication[125] and are not applicable to typical buildings, where outdoor-to-indoor air exchange already removes VOCs at a rate that could only be matched by the placement of 10–1000 plants/m2 of a building's floor space.[126]

Plants also appear to reduce airborne microbes and molds, and to increase humidity.[127] However, the increased humidity can itself lead to increased levels of mold and even VOCs.[128]

Since extremely high humidity is associated with increased mold growth, allergic responses, and respiratory responses, the presence of additional moisture from houseplants may not be desirable in all indoor settings if watering is done inappropriately.[129]

Institutional programs

[edit]
EPA graphic about asthma triggers

The topic of IAQ has become popular due to the greater awareness of health problems caused by mold and triggers to asthma and allergies.

In the US, the Environmental Protection Agency (EPA) has developed an "IAQ Tools for Schools" program to help improve the indoor environmental conditions in educational institutions. The National Institute for Occupational Safety and Health conducts Health Hazard Evaluations (HHEs) in workplaces at the request of employees, authorized representative of employees, or employers, to determine whether any substance normally found in the place of employment has potentially toxic effects, including indoor air quality.[130]

A variety of scientists work in the field of indoor air quality, including chemists, physicists, mechanical engineers, biologists, bacteriologists, epidemiologists, and computer scientists. Some of these professionals are certified by organizations such as the American Industrial Hygiene Association, the American Indoor Air Quality Council and the Indoor Environmental Air Quality Council.

In the UK, under the Department for Environment Food and Rural Affairs, the Air Quality Expert Group considers current knowledge on indoor air quality and provides advice to government and devolved administration ministers.[131]

At the international level, the International Society of Indoor Air Quality and Climate (ISIAQ), formed in 1991, organizes two major conferences, the Indoor Air and the Healthy Buildings series.[132]

See also

[edit]

References

[edit]
  1. ^ Carroll, GT; Kirschman, DL; Mammana, A (2022). "Increased CO2 levels in the operating room correlate with the number of healthcare workers present: an imperative for intentional crowd control". Patient Safety in Surgery. 16 (35): 35. doi:10.1186/s13037-022-00343-8. PMC 9672642. PMID 36397098.
  2. ^ ANSI/ASHRAE Standard 62.1, Ventilation for Acceptable Indoor Air Quality, ASHRAE, Inc., Atlanta, GA, US
  3. ^ Belias, Evangelos; Licina, Dusan (2022). "Outdoor PM2. 5 air filtration: optimising indoor air quality and energy". Building & Cities. 3 (1): 186–203. doi:10.5334/bc.153.
  4. ^ KMC Controls (September 24, 2015). "What's Your IQ on IAQ and IEQ?". Archived from the original on April 12, 2021. Retrieved April 12, 2021.[unreliable source?]
  5. ^ Bruce, N; Perez-Padilla, R; Albalak, R (2000). "Indoor air pollution in developing countries: a major environmental and public health challenge". Bulletin of the World Health Organization. 78 (9): 1078–92. PMC 2560841. PMID 11019457.
  6. ^ "Household air pollution and health: fact sheet". WHO. May 8, 2018. Archived from the original on November 12, 2021. Retrieved November 21, 2020.
  7. ^ Ritchie, Hannah; Roser, Max (2019). "Access to Energy". Our World in Data. Archived from the original on November 1, 2021. Retrieved April 1, 2021. According to the Global Burden of Disease study 1.6 million people died prematurely in 2017 as a result of indoor air pollution ... But it's worth noting that the WHO publishes a substantially larger number of indoor air pollution deaths..
  8. ^ Klepeis, Neil E; Nelson, William C; Ott, Wayne R; Robinson, John P; Tsang, Andy M; Switzer, Paul; Behar, Joseph V; Hern, Stephen C; Engelmann, William H (July 2001). "The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants". Journal of Exposure Science & Environmental Epidemiology. 11 (3): 231–252. Bibcode:2001JESEE..11..231K. doi:10.1038/sj.jea.7500165. PMID 11477521. S2CID 22445147. Archived from the original on March 28, 2023. Retrieved March 30, 2024.
  9. ^ U.S. Environmental Protection Agency. Office equipment: design, indoor air emissions, and pollution prevention opportunities. Air and Energy Engineering Research Laboratory, Research Triangle Park, 1995.
  10. ^ U.S. Environmental Protection Agency. Unfinished business: a comparative assessment of environmental problems, EPA-230/2-87-025a-e (NTIS PB88-127030). Office of Policy, Planning and Evaluation, Washington, DC, 1987.
  11. ^ Klepeis, Neil E; Nelson, William C; Ott, Wayne R; Robinson, John P; Tsang, Andy M; Switzer, Paul; Behar, Joseph V; Hern, Stephen C; Engelmann, William H (July 1, 2001). "The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants". Journal of Exposure Science & Environmental Epidemiology. 11 (3): 231–252. Bibcode:2001JESEE..11..231K. doi:10.1038/sj.jea.7500165. ISSN 1559-0631. PMID 11477521. Archived from the original on November 13, 2023. Retrieved November 13, 2023.
  12. ^ "Combined or multiple exposure to health stressors in indoor built environments: an evidence-based review prepared for the WHO training workshop "Multiple environmental exposures and risks": 16–18 October 2013, Bonn, Germany". World Health Organization. Regional Office for Europe. 2014. Archived from the original on November 6, 2023. Retrieved April 10, 2024.
  13. ^ "Household air pollution". World Health Organization. December 15, 2023. Archived from the original on November 12, 2021. Retrieved April 10, 2024.
  14. ^ Clark, Sierra N.; Lam, Holly C. Y.; Goode, Emma-Jane; Marczylo, Emma L.; Exley, Karen S.; Dimitroulopoulou, Sani (August 2, 2023). "The Burden of Respiratory Disease from Formaldehyde, Damp and Mould in English Housing". Environments. 10 (8): 136. doi:10.3390/environments10080136. ISSN 2076-3298.
  15. ^ "Chief Medical Officer (CMO): annual reports". GOV.UK. November 16, 2023. Retrieved May 5, 2024.
  16. ^ "Project information | Indoor air quality at home | Quality standards | NICE". www.nice.org.uk. Retrieved May 5, 2024.
  17. ^ "The inside story: Health effects of indoor air quality on children and young people". RCPCH. Retrieved May 5, 2024.
  18. ^ Halios, Christos H.; Landeg-Cox, Charlotte; Lowther, Scott D.; Middleton, Alice; Marczylo, Tim; Dimitroulopoulou, Sani (September 15, 2022). "Chemicals in European residences – Part I: A review of emissions, concentrations and health effects of volatile organic compounds (VOCs)". Science of the Total Environment. 839: 156201. Bibcode:2022ScTEn.83956201H. doi:10.1016/j.scitotenv.2022.156201. ISSN 0048-9697. PMID 35623519.
  19. ^ "Literature review on chemical pollutants in indoor air in public settings for children and overview of their health effects with a focus on schools, kindergartens and day-care centres". www.who.int. Retrieved May 5, 2024.
  20. ^ Burge, P S (February 2004). "Sick building syndrome". Occupational and Environmental Medicine. 61 (2): 185–190. doi:10.1136/oem.2003.008813. PMC 1740708. PMID 14739390.
  21. ^ Apte, K; Salvi, S (2016). "Household air pollution and its effects on health". F1000Research. 5: 2593. doi:10.12688/f1000research.7552.1. PMC 5089137. PMID 27853506. Burning of natural gas not only produces a variety of gases such as sulfur oxides, mercury compounds, and particulate matter but also leads to the production of nitrogen oxides, primarily nitrogen dioxide...The burning of biomass fuel or any other fossil fuel increases the concentration of black carbon in the air
  22. ^ "Improved Clean Cookstoves". Project Drawdown. February 7, 2020. Archived from the original on December 15, 2021. Retrieved December 5, 2020.
  23. ^ WHO indoor air quality guidelines: household fuel combustion. Geneva: World Health Organization. 2014. ISBN 978-92-4-154888-5.
  24. ^ "Clearing the Air: Gas Cooking and Pollution in European Homes". CLASP. November 8, 2023. Retrieved May 5, 2024.
  25. ^ Seals, Brady; Krasner, Andee. "Gas Stoves: Health and Air Quality Impacts and Solutions". RMI. Retrieved May 5, 2024.
  26. ^ a b c Myers, Isabella (February 2022). The efficient operation of regulation and legislation: An holistic approach to understanding the effect of Carbon Monoxide on mortality (PDF). CO Research Trust.
  27. ^ a b c Penney, David; Benignus, Vernon; Kephalopoulos, Stylianos; Kotzias, Dimitrios; Kleinman, Michael; Verrier, Agnes (2010), "Carbon monoxide", WHO Guidelines for Indoor Air Quality: Selected Pollutants, World Health Organization, ISBN 978-92-890-0213-4, OCLC 696099951, archived from the original on March 8, 2021, retrieved March 18, 2024
  28. ^ "Carbon monoxide: toxicological overview". UK Health Security Agency. May 24, 2022. Retrieved April 17, 2024.
  29. ^ a b c WHO global air quality guidelines: particulate matter (PM2.5 and PM10), ozone, nitrogen dioxide, sulfur dioxide and carbon monoxide (PDF). World Health Organization. 2021. hdl:10665/345329. ISBN 978-92-4-003422-8.[page needed]
  30. ^ a b Soleimani, Farshid; Dobaradaran, Sina; De-la-Torre, Gabriel E.; Schmidt, Torsten C.; Saeedi, Reza (March 2022). "Content of toxic components of cigarette, cigarette smoke vs cigarette butts: A comprehensive systematic review". Science of the Total Environment. 813: 152667. Bibcode:2022ScTEn.81352667S. doi:10.1016/j.scitotenv.2021.152667. PMID 34963586.
  31. ^ "Considering smoking as an air pollution problem for environmental health | Environmental Performance Index". Archived from the original on September 25, 2018. Retrieved March 21, 2018.
  32. ^ Arfaeinia, Hossein; Ghaemi, Maryam; Jahantigh, Anis; Soleimani, Farshid; Hashemi, Hassan (June 12, 2023). "Secondhand and thirdhand smoke: a review on chemical contents, exposure routes, and protective strategies". Environmental Science and Pollution Research. 30 (32): 78017–78029. Bibcode:2023ESPR...3078017A. doi:10.1007/s11356-023-28128-1. PMC 10258487. PMID 37306877.
  33. ^ Arfaeinia, Hossein; Ghaemi, Maryam; Jahantigh, Anis; Soleimani, Farshid; Hashemi, Hassan (June 12, 2023). "Secondhand and thirdhand smoke: a review on chemical contents, exposure routes, and protective strategies". Environmental Science and Pollution Research. 30 (32): 78017–78029. Bibcode:2023ESPR...3078017A. doi:10.1007/s11356-023-28128-1. ISSN 1614-7499. PMC 10258487. PMID 37306877.
  34. ^ Health, CDC's Office on Smoking and (May 9, 2018). "Smoking and Tobacco Use; Fact Sheet; Secondhand Smoke". Smoking and Tobacco Use. Archived from the original on December 15, 2021. Retrieved January 14, 2019.
  35. ^ Fernández, E; Ballbè, M; Sureda, X; Fu, M; Saltó, E; Martínez-Sánchez, JM (December 2015). "Particulate Matter from Electronic Cigarettes and Conventional Cigarettes: a Systematic Review and Observational Study". Current Environmental Health Reports. 2 (4): 423–9. Bibcode:2015CEHR....2..423F. doi:10.1007/s40572-015-0072-x. PMID 26452675.
  36. ^ Vu, Tuan V.; Harrison, Roy M. (May 8, 2019). "Chemical and Physical Properties of Indoor Aerosols". In Harrison, R. M.; Hester, R. E. (eds.). Indoor Air Pollution. The Royal Society of Chemistry (published 2019). ISBN 978-1-78801-803-6.
  37. ^ Abdullahi, Karimatu L.; Delgado-Saborit, Juana Maria; Harrison, Roy M. (February 13, 2013). "Emissions and indoor concentrations of particulate matter and its specific chemical components from cooking: A review". Atmospheric Environment. 71: 260–294. Bibcode:2013AtmEn..71..260A. doi:10.1016/j.atmosenv.2013.01.061. Archived from the original on May 21, 2023. Retrieved April 11, 2024.
  38. ^ Patel, Sameer; Sankhyan, Sumit; Boedicker, Erin K.; DeCarlo, Peter F.; Farmer, Delphine K.; Goldstein, Allen H.; Katz, Erin F.; Nazaroff, William W; Tian, Yilin; Vanhanen, Joonas; Vance, Marina E. (June 16, 2020). "Indoor Particulate Matter during HOMEChem: Concentrations, Size Distributions, and Exposures". Environmental Science & Technology. 54 (12): 7107–7116. Bibcode:2020EnST...54.7107P. doi:10.1021/acs.est.0c00740. ISSN 0013-936X. PMID 32391692. Archived from the original on April 28, 2023. Retrieved April 11, 2024.
  39. ^ Thangavel, Prakash; Park, Duckshin; Lee, Young-Chul (June 19, 2022). "Recent Insights into Particulate Matter (PM2.5)-Mediated Toxicity in Humans: An Overview". International Journal of Environmental Research and Public Health. 19 (12): 7511. doi:10.3390/ijerph19127511. ISSN 1660-4601. PMC 9223652. PMID 35742761.
  40. ^ You, Bo; Zhou, Wei; Li, Junyao; Li, Zhijie; Sun, Yele (November 4, 2022). "A review of indoor Gaseous organic compounds and human chemical Exposure: Insights from Real-time measurements". Environment International. 170: 107611. Bibcode:2022EnInt.17007611Y. doi:10.1016/j.envint.2022.107611. PMID 36335895.
  41. ^ Weschler, Charles J.; Carslaw, Nicola (March 6, 2018). "Indoor Chemistry". Environmental Science & Technology. 52 (5): 2419–2428. Bibcode:2018EnST...52.2419W. doi:10.1021/acs.est.7b06387. ISSN 0013-936X. PMID 29402076. Archived from the original on November 15, 2023. Retrieved April 11, 2024.
  42. ^ a b Carter, Toby J.; Poppendieck, Dustin G.; Shaw, David; Carslaw, Nicola (January 16, 2023). "A Modelling Study of Indoor Air Chemistry: The Surface Interactions of Ozone and Hydrogen Peroxide". Atmospheric Environment. 297: 119598. Bibcode:2023AtmEn.29719598C. doi:10.1016/j.atmosenv.2023.119598.
  43. ^ Tsai, Wen-Tien (March 26, 2019). "An overview of health hazards of volatile organic compounds regulated as indoor air pollutants". Reviews on Environmental Health. 34 (1): 81–89. doi:10.1515/reveh-2018-0046. PMID 30854833.
  44. ^ "U.S. EPA IAQ – Organic chemicals". Epa.gov. August 5, 2010. Archived from the original on September 9, 2015. Retrieved March 2, 2012.
  45. ^ a b Davies, Helen L.; O'Leary, Catherine; Dillon, Terry; Shaw, David R.; Shaw, Marvin; Mehra, Archit; Phillips, Gavin; Carslaw, Nicola (August 14, 2023). "A measurement and modelling investigation of the indoor air chemistry following cooking activities". Environmental Science: Processes & Impacts. 25 (9): 1532–1548. doi:10.1039/D3EM00167A. ISSN 2050-7887. PMID 37609942.
  46. ^ a b c Harding-Smith, Ellen; Shaw, David R.; Shaw, Marvin; Dillon, Terry J.; Carslaw, Nicola (January 23, 2024). "Does green mean clean? Volatile organic emissions from regular versus green cleaning products". Environmental Science: Processes & Impacts. 26 (2): 436–450. doi:10.1039/D3EM00439B. ISSN 2050-7887. PMID 38258874.
  47. ^ Lebel, Eric D.; Michanowicz, Drew R.; Bilsback, Kelsey R.; Hill, Lee Ann L.; Goldman, Jackson S. W.; Domen, Jeremy K.; Jaeger, Jessie M.; Ruiz, Angélica; Shonkoff, Seth B. C. (November 15, 2022). "Composition, Emissions, and Air Quality Impacts of Hazardous Air Pollutants in Unburned Natural Gas from Residential Stoves in California". Environmental Science & Technology. 56 (22): 15828–15838. Bibcode:2022EnST...5615828L. doi:10.1021/acs.est.2c02581. ISSN 0013-936X. PMC 9671046. PMID 36263944.
  48. ^ "Volatile Organic Compounds' Impact on Indoor Air Quality". United States Environmental Protection Agency. August 18, 2014. Retrieved May 23, 2024.
  49. ^ "About VOCs". January 21, 2013. Archived from the original on January 21, 2013. Retrieved September 16, 2019.
  50. ^ Oanh, Nguyen Thi Kim; Hung, Yung-Tse (2005). "Indoor Air Pollution Control". Advanced Air and Noise Pollution Control. Handbook of Environmental Engineering. Vol. 2. pp. 237–272. doi:10.1007/978-1-59259-779-6_7. ISBN 978-1-58829-359-6.
  51. ^ "Emicode". Eurofins.com. Archived from the original on September 24, 2015. Retrieved March 2, 2012.
  52. ^ "M1". Eurofins.com. Archived from the original on September 24, 2015. Retrieved March 2, 2012.
  53. ^ "Blue Angel". Eurofins.com. Archived from the original on September 24, 2015. Retrieved March 2, 2012.
  54. ^ "Indoor Air Comfort". Indoor Air Comfort. Archived from the original on February 1, 2011. Retrieved March 2, 2012.
  55. ^ "CDPH Section 01350". Eurofins.com. Archived from the original on September 24, 2015. Retrieved March 2, 2012.
  56. ^ a b "Smelly Moldy Houses". Archived from the original on December 15, 2021. Retrieved August 2, 2014.
  57. ^ Meruva, N. K.; Penn, J. M.; Farthing, D. E. (November 2004). "Rapid identification of microbial VOCs from tobacco molds using closed-loop stripping and gas chromatography/time-of-flight mass spectrometry". J Ind Microbiol Biotechnol. 31 (10): 482–8. doi:10.1007/s10295-004-0175-0. PMID 15517467. S2CID 32543591.
  58. ^ "Atmospheric carbon dioxide passes 400 ppm everywhere". Physics Today (6): 8170. 2016. Bibcode:2016PhT..2016f8170.. doi:10.1063/pt.5.029904.
  59. ^ Xie Y, Li Y, Feng Y, Cheng W, Wang Y (April 2022). "Inhalable microplastics prevails in air: Exploring the size detection limit". Environ Int. 162: 107151. Bibcode:2022EnInt.16207151X. doi:10.1016/j.envint.2022.107151. PMID 35228011.
  60. ^ Liu C, Li J, Zhang Y, Wang L, Deng J, Gao Y, Yu L, Zhang J, Sun H (July 2019). "Widespread distribution of PET and PC microplastics in dust in urban China and their estimated human exposure". Environ Int. 128: 116–124. Bibcode:2019EnInt.128..116L. doi:10.1016/j.envint.2019.04.024. PMID 31039519.
  61. ^ Yuk, Hyeonseong; Jo, Ho Hyeon; Nam, Jihee; Kim, Young Uk; Kim, Sumin (2022). "Microplastic: A particulate matter(PM) generated by deterioration of building materials". Journal of Hazardous Materials. 437. Elsevier BV: 129290. Bibcode:2022JHzM..43729290Y. doi:10.1016/j.jhazmat.2022.129290. ISSN 0304-3894. PMID 35753297.
  62. ^ Eberhard, Tiffany; Casillas, Gaston; Zarus, Gregory M.; Barr, Dana Boyd (January 6, 2024). "Systematic review of microplastics and nanoplastics in indoor and outdoor air: identifying a framework and data needs for quantifying human inhalation exposures" (PDF). Journal of Exposure Science & Environmental Epidemiology. 34 (2). Springer Science and Business Media LLC: 185–196. doi:10.1038/s41370-023-00634-x. ISSN 1559-0631. Retrieved December 19, 2024. MPs have been found in water and soil, and recent research is exposing the vast amount of them in ambient and indoor air.
  63. ^ Gasperi, Johnny; Wright, Stephanie L.; Dris, Rachid; Collard, France; Mandin, Corinne; Guerrouache, Mohamed; Langlois, Valérie; Kelly, Frank J.; Tassin, Bruno (2018). "Microplastics in air: Are we breathing it in?" (PDF). Current Opinion in Environmental Science & Health. 1: 1–5. Bibcode:2018COESH...1....1G. doi:10.1016/j.coesh.2017.10.002. S2CID 133750509. Archived (PDF) from the original on March 6, 2020. Retrieved July 11, 2019.
  64. ^ Prasittisopin, Lapyote; Ferdous, Wahid; Kamchoom, Viroon (2023). "Microplastics in construction and built environment". Developments in the Built Environment. 15. Elsevier BV. doi:10.1016/j.dibe.2023.100188. ISSN 2666-1659.
  65. ^ Galloway, Nanette LoBiondo (September 13, 2024). "Ventnor introduces ordinance to control microplastics contamination". DownBeach. Retrieved October 2, 2024.
  66. ^ Weschler, Charles J. (December 2000). "Ozone in Indoor Environments: Concentration and Chemistry: Ozone in Indoor Environments". Indoor Air. 10 (4): 269–288. doi:10.1034/j.1600-0668.2000.010004269.x. PMID 11089331. Archived from the original on April 15, 2024. Retrieved April 11, 2024.
  67. ^ Weschler, Charles J.; Nazaroff, William W (February 22, 2023). "Human skin oil: a major ozone reactant indoors". Environmental Science: Atmospheres. 3 (4): 640–661. doi:10.1039/D3EA00008G. ISSN 2634-3606. Archived from the original on April 15, 2024. Retrieved April 11, 2024.
  68. ^ Kumar, Prashant; Kalaiarasan, Gopinath; Porter, Alexandra E.; Pinna, Alessandra; KÅ‚osowski, MichaÅ‚ M.; Demokritou, Philip; Chung, Kian Fan; Pain, Christopher; Arvind, D. K.; Arcucci, Rossella; Adcock, Ian M.; Dilliway, Claire (February 20, 2021). "An overview of methods of fine and ultrafine particle collection for physicochemical characterisation and toxicity assessments". Science of the Total Environment. 756: 143553. Bibcode:2021ScTEn.75643553K. doi:10.1016/j.scitotenv.2020.143553. hdl:10044/1/84518. PMID 33239200. S2CID 227176222.
  69. ^ Apte, M. G.; Buchanan, I. S. H.; Mendell, M. J. (April 2008). "Outdoor ozone and building-related symptoms in the BASE study". Indoor Air. 18 (2): 156–170. Bibcode:2008InAir..18..156A. doi:10.1111/j.1600-0668.2008.00521.x. PMID 18333994.
  70. ^ "Eight-hour Average Ozone Concentrations | Ground-level Ozone | New England | US EPA". United States Environmental Protection Agency. Archived from the original on December 15, 2021. Retrieved September 16, 2019.
  71. ^ a b c Park, J. H.; Cox-Ganser, J. M. (2011). "Meta-Mold exposure and respiratory health in damp indoor environments". Frontiers in Bioscience. 3 (2): 757–771. doi:10.2741/e284. PMID 21196349.
  72. ^ "CDC – Mold – General Information – Facts About Mold and Dampness". December 4, 2018. Archived from the original on December 16, 2019. Retrieved June 23, 2017.
  73. ^ Singh, Dr Jagjit; Singh, Jagjit, eds. (1994). Building Mycology (1 ed.). Taylor & Francis. doi:10.4324/9780203974735. ISBN 978-1-135-82462-4.
  74. ^ a b Clarke, J.A; Johnstone, C.M; Kelly, N.J; McLean, R.C; anderson, J.A; Rowan, N.J; Smith, J.E (January 20, 1999). "A technique for the prediction of the conditions leading to mould growth in buildings". Building and Environment. 34 (4): 515–521. Bibcode:1999BuEnv..34..515C. doi:10.1016/S0360-1323(98)00023-7. Archived from the original on October 26, 2022. Retrieved April 10, 2024.
  75. ^ Vereecken, Evy; Roels, Staf (November 15, 2011). "Review of mould prediction models and their influence on mould risk evaluation". Building and Environment. 51: 296–310. doi:10.1016/j.buildenv.2011.11.003. Archived from the original on March 2, 2024. Retrieved April 11, 2024.
  76. ^ BS 5250:2021 - Management of moisture in buildings. Code of practice. British Standards Institution (BSI). October 31, 2021. ISBN 978-0-539-18975-9.
  77. ^ Madgwick, Della; Wood, Hannah (August 8, 2016). "The problem of clothes drying in new homes in the UK". Structural Survey. 34 (4/5): 320–330. doi:10.1108/SS-10-2015-0048. ISSN 0263-080X. Archived from the original on May 7, 2021. Retrieved April 11, 2024.
  78. ^ May, Neil; McGilligan, Charles; Ucci, Marcella (2017). "Health and Moisture in Buildings" (PDF). UK Centre for Moisture in Buildings. Archived (PDF) from the original on April 11, 2024. Retrieved April 11, 2024.
  79. ^ "Understanding and addressing the health risks of damp and mould in the home". GOV.UK. September 7, 2023. Archived from the original on April 10, 2024. Retrieved April 11, 2024.
  80. ^ Clark, Sierra N.; Lam, Holly C. Y.; Goode, Emma-Jane; Marczylo, Emma L.; Exley, Karen S.; Dimitroulopoulou, Sani (August 2, 2023). "The Burden of Respiratory Disease from Formaldehyde, Damp and Mould in English Housing". Environments. 10 (8): 136. doi:10.3390/environments10080136. ISSN 2076-3298.
  81. ^ Microbiology of the Indoor Environment Archived July 23, 2011, at the Wayback Machine, microbe.net
  82. ^ http://www.info.gov.hk/info/sars/pdf/amoy_e.pdf
  83. ^ https://www.info.gov.hk/info/sars/graphics/amoyannex.jpg
  84. ^ "Progress in Global Surveillance and Response Capacity 10 Years after Severe Acute Respiratory Syndrome". environmental contamination with SARS CoV RNA was identified on the carpet in front of the index case-patient's room and 3 nearby rooms (and on their door frames but not inside the rooms) and in the air intake vents near the centrally located elevators ... secondary infections occurred not in guest rooms but in the common areas of the ninth floor, such as the corridor or elevator hall. These areas could have been contaminated through body fluids (e.g., vomitus, expectorated sputum), respiratory droplets, or suspended small-particle aerosols generated by the index case-patient; other guests were then infected by fomites or aerosols while passing through these same areas. Efficient spread of SARS CoV through small-particle aerosols was observed in several superspreading events in health care settings, during an airplane flight, and in an apartment complex (12–14,16–19). This process of environmental contamination that generated infectious aerosols likely best explains the pattern of disease transmission at the Hotel Metropole.
  85. ^ Azuma, Kenichi; Kagi, Naoki; Yanagi, U.; Osawa, Haruki (December 2018). "Effects of low-level inhalation exposure to carbon dioxide in indoor environments: A short review on human health and psychomotor performance". Environment International. 121 (Pt 1): 51–56. Bibcode:2018EnInt.121...51A. doi:10.1016/j.envint.2018.08.059. PMID 30172928.
  86. ^ Du, Bowen; Tandoc, Michael (June 19, 2020). "Indoor CO2 concentrations and cognitive function: A critical review". International Journal of Indoor Environment and Health. 30 (6): 1067–1082. Bibcode:2020InAir..30.1067D. doi:10.1111/ina.12706. PMID 32557862. S2CID 219915861.
  87. ^ Fan, Yuejie; Cao, Xiaodong; Zhang, Jie; Lai, Dayi; Pang, Liping (June 1, 2023). "Short-term exposure to indoor carbon dioxide and cognitive task performance: A systematic review and meta-analysis". Building and Environment. 237: 110331. Bibcode:2023BuEnv.23710331F. doi:10.1016/j.buildenv.2023.110331.
  88. ^ a b Lowther, Scott D.; Dimitroulopoulou, Sani; Foxall, Kerry; Shrubsole, Clive; Cheek, Emily; Gadeberg, Britta; Sepai, Ovnair (November 16, 2021). "Low Level Carbon Dioxide Indoors—A Pollution Indicator or a Pollutant? A Health-Based Perspective". Environments. 8 (11): 125. doi:10.3390/environments8110125. ISSN 2076-3298.
  89. ^ Persily, Andrew (July 2022). "Development and application of an indoor carbon dioxide metric". Indoor Air. 32 (7): e13059. doi:10.1111/ina.13059. PMID 35904382.
  90. ^ "Indoor Environmental Quality: HVAC Management | NIOSH | CDC". www.cdc.gov. February 25, 2022. Archived from the original on April 1, 2022. Retrieved April 1, 2022.
  91. ^ Indoor Environmental Quality: Building Ventilation Archived January 20, 2022, at the Wayback Machine. National Institute for Occupational Safety and Health. Accessed October 8, 2008.
  92. ^ "SAMHE - Schools' Air quality Monitoring for Health and Education". samhe.org.uk. Archived from the original on March 18, 2024. Retrieved March 18, 2024.
  93. ^ "Document Display | NEPIS | US EPA". nepis.epa.gov. Archived from the original on November 16, 2023. Retrieved October 19, 2023.
  94. ^ Zeeb & Shannoun 2009, p. 3.
  95. ^ C.Michael Hogan and Sjaak Slanina. 2010, Air pollution. Encyclopedia of Earth Archived October 12, 2006, at the Wayback Machine. eds. Sidney Draggan and Cutler Cleveland. National Council for Science and the Environment. Washington DC
  96. ^ "Radon Mitigation Methods". Radon Solution—Raising Radon Awareness. Archived from the original on December 15, 2008. Retrieved December 2, 2008.
  97. ^ Zeeb & Shannoun 2009, p. [page needed].
  98. ^ "Basic radon facts" (PDF). US Environmental Protection Agency. Archived (PDF) from the original on January 13, 2022. Retrieved September 18, 2018. Public Domain This article incorporates text from this source, which is in the public domain.
  99. ^ "Radon Action Level and Target Level". UKradon. Archived from the original on March 18, 2024. Retrieved March 18, 2024.
  100. ^ "Radon Zone Map (with State Information)". U.S. Environmental Protection Agency. Archived from the original on April 1, 2023. Retrieved April 10, 2024.
  101. ^ "UK maps of radon". UKradon. Archived from the original on March 7, 2024. Retrieved April 10, 2024.
  102. ^ "Radon map of Australia". Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Archived from the original on March 20, 2024. Retrieved April 10, 2024.
  103. ^ "Climate Change 2021: The Physical Science Basis". Intergovernmental Panel on Climate Change. Archived (PDF) from the original on May 26, 2023. Retrieved April 15, 2024.
  104. ^ Chen, Guochao; Qiu, Minghao; Wang, Peng; Zhang, Yuqiang; Shindell, Drew; Zhang, Hongliang (July 19, 2024). "Continuous wildfires threaten public and ecosystem health under climate change across continents". Frontiers of Environmental Science & Engineering. 18 (10). doi:10.1007/s11783-024-1890-6. ISSN 2095-2201.
  105. ^ Gherasim, Alina; Lee, Alison G.; Bernstein, Jonathan A. (November 14, 2023). "Impact of Climate Change on Indoor Air Quality". Immunology and Allergy Clinics of North America. 44 (1): 55–73. doi:10.1016/j.iac.2023.09.001. PMID 37973260. Archived from the original on November 15, 2023. Retrieved April 15, 2024.
  106. ^ Lacressonnière, Gwendoline; Watson, Laura; Gauss, Michael; Engardt, Magnuz; Andersson, Camilla; Beekmann, Matthias; Colette, Augustin; Foret, Gilles; Josse, Béatrice; Marécal, Virginie; Nyiri, Agnes; Siour, Guillaume; Sobolowski, Stefan; Vautard, Robert (February 1, 2017). "Particulate matter air pollution in Europe in a +2 °C warming world". Atmospheric Environment. 154: 129–140. Bibcode:2017AtmEn.154..129L. doi:10.1016/j.atmosenv.2017.01.037. Archived from the original on November 17, 2023. Retrieved April 15, 2024.
  107. ^ Lee, J; Lewis, A; Monks, P; Jacob, M; Hamilton, J; Hopkins, J; Watson, N; Saxton, J; Ennis, C; Carpenter, L (September 26, 2006). "Ozone photochemistry and elevated isoprene during the UK heatwave of august 2003". Atmospheric Environment. 40 (39): 7598–7613. Bibcode:2006AtmEn..40.7598L. doi:10.1016/j.atmosenv.2006.06.057. Archived from the original on October 26, 2022. Retrieved April 15, 2024.
  108. ^ Salthammer, Tunga; Schieweck, Alexandra; Gu, Jianwei; Ameri, Shaghayegh; Uhde, Erik (August 7, 2018). "Future trends in ambient air pollution and climate in Germany – Implications for the indoor environment". Building and Environment. 143: 661–670. Bibcode:2018BuEnv.143..661S. doi:10.1016/j.buildenv.2018.07.050.
  109. ^ Zhong, L.; Lee, C.-S.; Haghighat, F. (December 1, 2016). "Indoor ozone and climate change". Sustainable Cities and Society. 28: 466–472. doi:10.1016/j.scs.2016.08.020. Archived from the original on November 28, 2022. Retrieved April 15, 2024.
  110. ^ Zhao, Jiangyue; Uhde, Erik; Salthammer, Tunga; Antretter, Florian; Shaw, David; Carslaw, Nicola; Schieweck, Alexandra (December 9, 2023). "Long-term prediction of the effects of climate change on indoor climate and air quality". Environmental Research. 243: 117804. doi:10.1016/j.envres.2023.117804. PMID 38042519.
  111. ^ Niculita-Hirzel, Hélène (March 16, 2022). "Latest Trends in Pollutant Accumulations at Threatening Levels in Energy-Efficient Residential Buildings with and without Mechanical Ventilation: A Review". International Journal of Environmental Research and Public Health. 19 (6): 3538. doi:10.3390/ijerph19063538. ISSN 1660-4601. PMC 8951331. PMID 35329223.
  112. ^ UK Health Security Agency (2024) [1 September 2012]. "Chapter 5: Impact of climate change policies on indoor environmental quality and health in UK housing". Health Effects of Climate Change (HECC) in the UK: 2023 report (published January 15, 2024).
  113. ^ World Health Organization, ed. (2010). Who guidelines for indoor air quality: selected pollutants. Copenhagen: WHO. ISBN 978-92-890-0213-4. OCLC 696099951.
  114. ^ "Air quality: UK guidelines for volatile organic compounds in indoor spaces". Public Health England. September 13, 2019. Retrieved April 17, 2024.
  115. ^ "Home - IEQ Guidelines". ieqguidelines.org. Retrieved April 17, 2024.
  116. ^ Toyinbo, Oluyemi; Hägerhed, Linda; Dimitroulopoulou, Sani; Dudzinska, Marzenna; Emmerich, Steven; Hemming, David; Park, Ju-Hyeong; Haverinen-Shaughnessy, Ulla; the Scientific Technical Committee 34 of the International Society of Indoor Air Quality, Climate (April 19, 2022). "Open database for international and national indoor environmental quality guidelines". Indoor Air. 32 (4): e13028. doi:10.1111/ina.13028. ISSN 0905-6947. PMC 11099937. PMID 35481936.cite journal: CS1 maint: numeric names: authors list (link)
  117. ^ Dimitroulopoulou, Sani; DudziÅ„ska, Marzenna R.; Gunnarsen, Lars; Hägerhed, Linda; Maula, Henna; Singh, Raja; Toyinbo, Oluyemi; Haverinen-Shaughnessy, Ulla (August 4, 2023). "Indoor air quality guidelines from across the world: An appraisal considering energy saving, health, productivity, and comfort". Environment International. 178: 108127. Bibcode:2023EnInt.17808127D. doi:10.1016/j.envint.2023.108127. PMID 37544267.
  118. ^ Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque (February 2017). "Monitoring Indoor Air Quality for Enhanced Occupational Health". Journal of Medical Systems. 41 (2): 23. doi:10.1007/s10916-016-0667-2. PMID 28000117. S2CID 7372403.
  119. ^ Wyon, D. P. (August 2004). "The effects of indoor air quality on performance and productivity: The effects of IAQ on performance and productivity". Indoor Air. 14: 92–101. doi:10.1111/j.1600-0668.2004.00278.x. PMID 15330777.
  120. ^ Son, Young Joo; Pope, Zachary C.; Pantelic, Jovan (September 2023). "Perceived air quality and satisfaction during implementation of an automated indoor air quality monitoring and control system". Building and Environment. 243: 110713. Bibcode:2023BuEnv.24310713S. doi:10.1016/j.buildenv.2023.110713.
  121. ^ IAQM (2021). Indoor Air Quality Guidance: Assessment, Monitoring, Modelling and Mitigation (PDF) (Version 0.1 ed.). London: Institute of Air Quality Management.
  122. ^ a b Institute for Occupational Safety and Health of the German Social Accident Insurance. "Indoor workplaces – Recommended procedure for the investigation of working environment". Archived from the original on November 3, 2021. Retrieved June 10, 2020.
  123. ^ "Climate Change: Atmospheric Carbon Dioxide | NOAA Climate.gov". www.climate.gov. April 9, 2024. Retrieved May 6, 2024.
  124. ^ "Ventilation to reduce the spread of respiratory infections, including COVID-19". GOV.UK. August 2, 2022. Archived from the original on January 18, 2024. Retrieved April 15, 2024.
  125. ^ Dela Cruz, Majbrit; Christensen, Jan H.; Thomsen, Jane Dyrhauge; Müller, Renate (December 2014). "Can ornamental potted plants remove volatile organic compounds from indoor air? — a review". Environmental Science and Pollution Research. 21 (24): 13909–13928. Bibcode:2014ESPR...2113909D. doi:10.1007/s11356-014-3240-x. PMID 25056742. S2CID 207272189.
  126. ^ Cummings, Bryan E.; Waring, Michael S. (March 2020). "Potted plants do not improve indoor air quality: a review and analysis of reported VOC removal efficiencies". Journal of Exposure Science & Environmental Epidemiology. 30 (2): 253–261. Bibcode:2020JESEE..30..253C. doi:10.1038/s41370-019-0175-9. PMID 31695112. S2CID 207911697.
  127. ^ Wolverton, B. C.; Wolverton, J. D. (1996). "Interior plants: their influence on airborne microbes inside energy-efficient buildings". Journal of the Mississippi Academy of Sciences. 41 (2): 100–105.
  128. ^ US EPA, OAR (July 16, 2013). "Mold". US EPA. Archived from the original on May 18, 2020. Retrieved September 16, 2019.
  129. ^ Institute of Medicine (US) Committee on Damp Indoor Spaces and Health (2004). Damp Indoor Spaces and Health. National Academies Press. ISBN 978-0-309-09193-0. PMID 25009878. Archived from the original on January 19, 2023. Retrieved March 30, 2024.[page needed]
  130. ^ "Indoor Environmental Quality". Washington, DC: US National Institute for Occupational Safety and Health. Archived from the original on December 3, 2013. Retrieved May 17, 2013.
  131. ^ Lewis, Alastair C; Allan, James; Carslaw, David; Carruthers, David; Fuller, Gary; Harrison, Roy; Heal, Mathew; Nemitz, Eiko; Reeves, Claire (2022). Indoor Air Quality (PDF) (Report). Air Quality Expert Group. doi:10.5281/zenodo.6523605. Archived (PDF) from the original on June 5, 2023. Retrieved April 15, 2024.
  132. ^ "Isiaq.Org". International Society of Indoor Air Quality and Climate. Archived from the original on January 21, 2022. Retrieved March 2, 2012.

Sources

[edit]
Monographs
Articles, radio segments, web pages

Further reading

[edit]
[edit]

 

 

A digital thermostat
Honeywell's "The Round" model T87 thermostat, one of which is in the collection of the Smithsonian.
A touch screen thermostat
An electronic thermostat in a retail store

A thermostat is a regulating device component which senses the temperature of a physical system and performs actions so that the system's temperature is maintained near a desired setpoint.

Thermostats are used in any device or system that heats or cools to a setpoint temperature. Examples include building heating, central heating, air conditioners, HVAC systems, water heaters, as well as kitchen equipment including ovens and refrigerators and medical and scientific incubators. In scientific literature, these devices are often broadly classified as thermostatically controlled loads (TCLs). Thermostatically controlled loads comprise roughly 50% of the overall electricity demand in the United States.[1]

A thermostat operates as a "closed loop" control device, as it seeks to reduce the error between the desired and measured temperatures. Sometimes a thermostat combines both the sensing and control action elements of a controlled system, such as in an automotive thermostat. The word thermostat is derived from the Greek words θερμÏŒς thermos, "hot" and στατÏŒς statos, "standing, stationary".

Overview

[edit]

A thermostat exerts control by switching heating or cooling devices on or off, or by regulating the flow of a heat transfer fluid as needed, to maintain the correct temperature. A thermostat can often be the main control unit for a heating or cooling system, in applications ranging from ambient air control to automotive coolant control. Thermostats are used in any device or system that heats or cools to a setpoint temperature. Examples include building heating, central heating, and air conditioners, kitchen equipment such as ovens and refrigerators, and medical and scientific incubators.

Construction and control

[edit]

Thermostats use different types of sensors to measure temperatures and actuate control operations. Mechanical thermostats commonly use bimetallic strips, converting a temperature change into mechanical displacement, to actuate control of the heating or cooling sources. Electronic thermostats, instead, use a thermistor or other semiconductor sensor, processing temperature change as electronic signals, to control the heating or cooling equipment.

Conventional thermostats are example of "bang-bang controllers" as the controlled system either operates at full capacity once the setpoint is reached, or keeps completely off. Although it is the simplest program to implement, such control method requires to include some hysteresis in order to prevent excessively rapid cycling of the equipment around the setpoint. As a consequence, conventional thermostats cannot control temperatures very precisely. Instead, there are oscillations of a certain magnitude, usually 1-2 °C.[2] Such control is in general inaccurate, inefficient and may induce more mechanical wear; it however, allows for more cost-effective compressors compared to ones with continuously variable capacity.[3][clarification needed]

Another consideration is the time delay of the controlled system. To improve the control performance of the system, thermostats can include an "anticipator", which stops heating/cooling slightly earlier than reaching the setpoint, as the system will continue to produce heat for a short while.[4] Turning off exactly at the setpoint will cause actual temperature to exceed the desired range, known as "overshoot". Bimetallic sensors can include a physical "anticipator", which has a thin wire touched on the thermostat. When current passes the wire, a small amount of heat is generated and transferred to the bimetallic coil. Electronic thermostats have an electronic equivalent.[5]

When higher control precision is required, a PID or MPC controller is preferred. However, they are nowadays mainly adopted for industrial purposes, for example, for semiconductor manufacturing factories or museums.

Sensor types

[edit]

Early technologies included mercury thermometers with electrodes inserted directly through the glass, so that when a certain (fixed) temperature was reached the contacts would be closed by the mercury. These were accurate to within a degree of temperature.

Common sensor technologies in use today include:

These may then control the heating or cooling apparatus using:

  • Direct mechanical control
  • Electrical signals
  • Pneumatic signals

History

[edit]

Possibly the earliest recorded examples of thermostatic control were built by a Dutch innovator, Cornelis Drebbel (1572–1633), about 1620 in England. He invented a mercury thermostat to regulate the temperature of a chicken incubator.[6] This is one of the first recorded feedback-controlled devices.

Modern thermostatic control was developed in the 1830s by Andrew Ure (1778–1857), a Scottish chemist. The textile mills of the time needed a constant and steady temperature to operate optimally, so Ure designed the bimetallic thermostat, which would bend as one of the metals expanded in response to the increased temperature and cut off the energy supply.[7]

Warren S. Johnson (1847–1911), of Wisconsin, patented a bi-metal room thermostat in 1883, and two years later sought a patent for the first multi-zone thermostatic control system.[8][9] Albert Butz (1849–1905) invented the electric thermostat and patented it in 1886.

One of the first industrial uses of the thermostat was in the regulation of the temperature in poultry incubators. Charles Hearson, a British engineer, designed the first modern incubator for eggs, which was taken up for use on poultry farms in 1879.[10]

Mechanical thermostats

[edit]

This covers only devices which both sense and control using purely mechanical means.

Bimetal

[edit]

Domestic water and steam based central heating systems have traditionally been controlled by bi-metallic strip thermostats, and this is dealt with later in this article. Purely mechanical control has been localised steam or hot-water radiator bi-metallic thermostats which regulated the individual flow. However, thermostatic radiator valves (TRV) are now being widely used.

Purely mechanical thermostats are used to regulate dampers in some rooftop turbine vents, reducing building heat loss in cool or cold periods.

Some automobile passenger heating systems have a thermostatically controlled valve to regulate the water flow and temperature to an adjustable level. In older vehicles the thermostat controls the application of engine vacuum to actuators that control water valves and flappers to direct the flow of air. In modern vehicles, the vacuum actuators may be operated by small solenoids under the control of a central computer.

Wax pellet

[edit]

Automotive

[edit]
Car engine thermostat

Perhaps the most common example of purely mechanical thermostat technology in use today is the internal combustion engine cooling system thermostat, used to maintain the engine near its optimum operating temperature by regulating the flow of coolant to an air-cooled radiator. This type of thermostat operates using a sealed chamber containing a wax pellet that melts and expands at a set temperature. The expansion of the chamber operates a rod which opens a valve when the operating temperature is exceeded. The operating temperature is determined by the composition of the wax. Once the operating temperature is reached, the thermostat progressively increases or decreases its opening in response to temperature changes, dynamically balancing the coolant recirculation flow and coolant flow to the radiator to maintain the engine temperature in the optimum range.

On many automobile engines, including all Chrysler Group and General Motors products, the thermostat does not restrict flow to the heater core. The passenger side tank of the radiator is used as a bypass to the thermostat, flowing through the heater core. This prevents formation of steam pockets before the thermostat opens, and allows the heater to function before the thermostat opens. Another benefit is that there is still some flow through the radiator if the thermostat fails.

Shower and other hot water controls

[edit]

A thermostatic mixing valve uses a wax pellet to control the mixing of hot and cold water. A common application is to permit operation of an electric water heater at a temperature hot enough to kill Legionella bacteria (above 60 °C, 140 °F), while the output of the valve produces water that is cool enough to not immediately scald (49 °C, 120 °F).

Analysis

[edit]

A wax pellet driven valve can be analyzed through graphing the wax pellet's hysteresis which consists of two thermal expansion curves; extension (motion) vs. temperature increase, and contraction (motion) vs. temperature decrease. The spread between the up and down curves visually illustrate the valve's hysteresis; there is always hysteresis within wax driven valves due to the phase transition or phase change between solids and liquids. Hysteresis can be controlled with specialized blended mixes of hydrocarbons; tight hysteresis is what most desire, however some applications require broader ranges. Wax pellet driven valves are used in anti scald, freeze protection, over-temp purge, solar thermal energy or solar thermal, automotive, and aerospace applications among many others.

Gas expansion

[edit]

Thermostats are sometimes used to regulate gas ovens. It consists of a gas-filled bulb connected to the control unit by a slender copper tube. The bulb is normally located at the top of the oven. The tube ends in a chamber sealed by a diaphragm. As the thermostat heats up, the gas expands applying pressure to the diaphragm which reduces the flow of gas to the burner.

Pneumatic thermostats

[edit]

A pneumatic thermostat is a thermostat that controls a heating or cooling system via a series of air-filled control tubes. This "control air" system responds to the pressure changes (due to temperature) in the control tube to activate heating or cooling when required. The control air typically is maintained on "mains" at 15-18 psi (although usually operable up to 20 psi). Pneumatic thermostats typically provide output/ branch/ post-restrictor (for single-pipe operation) pressures of 3-15 psi which is piped to the end device (valve/ damper actuator/ pneumatic-electric switch, etc.).[11]

The pneumatic thermostat was invented by Warren Johnson in 1895[12] soon after he invented the electric thermostat. In 2009, Harry Sim was awarded a patent for a pneumatic-to-digital interface[13] that allows pneumatically controlled buildings to be integrated with building automation systems to provide similar benefits as direct digital control (DDC).

Electrical and analog electronic thermostats

[edit]

Bimetallic switching thermostats

[edit]
Bimetallic thermostat for buildings.

Water and steam based central heating systems have traditionally had overall control by wall-mounted bi-metallic strip thermostats. These sense the air temperature using the differential expansion of two metals to actuate an on/off switch.[14] Typically the central system would be switched on when the temperature drops below the setpoint on the thermostat, and switched off when it rises above, with a few degrees of hysteresis to prevent excessive switching. Bi-metallic sensing is now being superseded by electronic sensors. A principal use of the bi-metallic thermostat today is in individual electric convection heaters, where control is on/off, based on the local air temperature and the setpoint desired by the user. These are also used on air-conditioners, where local control is required.

Contact configuration nomenclature

[edit]

This follows the same nomenclature as described in Relay § Terminology and Switch § Contact terminology. A thermostat is considered to be activated by thermal energy, thus “normal” refers to the state in which temperature is below the setpoint.

  • "NO" stands for "normally open". This is the same as "COR" ("close on rise"). May be used to start a fan when it is becoming hot, and to stop the fan when it has become cold enough.
  • "NC" stands for "normally closed". This is the same as "OOR" ("open on rise"). May be used to start a heater when it is becoming cold, and to stop the heater when it has become warm enough.
  • "CO" stands for "change over". This serves both as "NO" and "NC". May be used to start a fan when it is becoming hot, but also (on the opposite terminal), to start a heater when it is becoming cold.

Any leading number stands for number of contact sets, like "1NO", "1NC" for one contact set with two terminals. "1CO" will also have one contact set, even if it is a switch-over with three terminals.

Simple two wire thermostats

[edit]
Millivolt thermostat mechanism

The illustration is the interior of a common two wire heat-only household thermostat, used to regulate a gas-fired heater via an electric gas valve. Similar mechanisms may also be used to control oil furnaces, boilers, boiler zone valves, electric attic fans, electric furnaces, electric baseboard heaters, and household appliances such as refrigerators, coffee pots and hair dryers. The power through the thermostat is provided by the heating device and may range from millivolts to 240 volts in common North American construction, and is used to control the heating system either directly (electric baseboard heaters and some electric furnaces) or indirectly (all gas, oil and forced hot water systems). Due to the variety of possible voltages and currents available at the thermostat, caution must be taken when selecting a replacement device.

  1. Setpoint control lever. This is moved to the right for a higher temperature. The round indicator pin in the center of the second slot shows through a numbered slot in the outer case.
  2. Bimetallic strip wound into a coil. The center of the coil is attached to a rotating post attached to lever (1). As the coil gets colder the moving end — carrying (4) — moves clockwise.
  3. Flexible wire. The left side is connected via one wire of a pair to the heater control valve.
  4. Moving contact attached to the bimetal coil. Thence, to the heater's controller.
  5. Fixed contact screw. This is adjusted by the manufacturer. It is connected electrically by a second wire of the pair to the thermocouple and the heater's electrically operated gas valve.
  6. Magnet. This ensures a good contact when the contact closes. It also provides hysteresis to prevent short heating cycles, as the temperature must be raised several degrees before the contacts will open. As an alternative, some thermostats instead use a mercury switch on the end of the bimetal coil. The weight of the mercury on the end of the coil tends to keep it there, also preventing short heating cycles. However, this type of thermostat is banned in many countries due to its highly and permanently toxic nature if broken. When replacing these thermostats they must be regarded as chemical waste.

Not shown in the illustration is a separate bimetal thermometer on the outer case to show the actual temperature at the thermostat.

Millivolt thermostats

[edit]

As illustrated in the use of the thermostat above, all of the power for the control system is provided by a thermopile which is a combination of many stacked thermocouples, heated by the pilot light. The thermopile produces sufficient electrical power to drive a low-power gas valve, which under control of one or more thermostat switches, in turn controls the input of fuel to the burner.

This type of device is generally considered obsolete as pilot lights can waste a surprising amount of gas (in the same way a dripping faucet can waste a large amount of water over an extended period), and are also no longer used on stoves, but are still to be found in many gas water heaters and gas fireplaces. Their poor efficiency is acceptable in water heaters, since most of the energy "wasted" on the pilot still represents a direct heat gain for the water tank. The Millivolt system also makes it unnecessary for a special electrical circuit to be run to the water heater or furnace; these systems are often completely self-sufficient and can run without any external electrical power supply. For tankless "on demand" water heaters, pilot ignition is preferable because it is faster than hot-surface ignition and more reliable than spark ignition.

Some programmable thermostats - those that offer simple "millivolt" or "two-wire" modes - will control these systems.

24-volt thermostats

[edit]

The majority of modern heating/cooling/heat pump thermostats operate on low voltage (typically 24 volts AC) control circuits. The source of the 24 volt AC power is a control transformer installed as part of the heating/cooling equipment. The advantage of the low voltage control system is the ability to operate multiple electromechanical switching devices such as relays, contactors, and sequencers using inherently safe voltage and current levels.[15] Built into the thermostat is a provision for enhanced temperature control using anticipation.

A heat anticipator generates a small amount of additional heat to the sensing element while the heating appliance is operating. This opens the heating contacts slightly early to prevent the space temperature from greatly overshooting the thermostat setting. A mechanical heat anticipator is generally adjustable and should be set to the current flowing in the heating control circuit when the system is operating.

A cooling anticipator generates a small amount of additional heat to the sensing element while the cooling appliance is not operating. This causes the contacts to energize the cooling equipment slightly early, preventing the space temperature from climbing excessively. Cooling anticipators are generally non-adjustable.

Electromechanical thermostats use resistance elements as anticipators. Most electronic thermostats use either thermistor devices or integrated logic elements for the anticipation function. In some electronic thermostats, the thermistor anticipator may be located outdoors, providing a variable anticipation depending on the outdoor temperature.

Thermostat enhancements include outdoor temperature display, programmability, and system fault indication. While such 24 volt thermostats are incapable of operating a furnace when the mains power fails, most such furnaces require mains power for heated air fans (and often also hot-surface or electronic spark ignition) rendering moot the functionality of the thermostat. In other circumstances such as piloted wall and "gravity" (fanless) floor and central heaters the low voltage system described previously may be capable of remaining functional when electrical power is unavailable.

There are no standards for wiring color codes, but convention has settled on the following terminal codes and colors.[16][17] In all cases, the manufacturer's instructions should be considered definitive.

Terminal code Color Description
R Red 24 volt (Return line to appliance; often strapped to Rh and Rc)
Rh Red 24 volt HEAT load (Return line Heat)
Rc Red 24 volt COOL load (Return line Cool)
C Black/Blue/Brown/Cyan 24 volt Common connection to relays
W / W1 White Heat
W2 Varies/White/Black 2nd Stage / Backup Heat
Y / Y1 Yellow Cool
Y2 Blue/Orange/Purple/Yellow/White 2nd Stage Cool
G Green Fan
O Varies/Orange/Black Reversing valve Energize to Cool (Heat Pump)
B Varies/Blue/Black/Brown/Orange Reversing valve Energize to Heat (Heat Pump) or Common
E Varies/Blue/Pink/Gray/Tan Emergency Heat (Heat Pump)
S1/S2 Brown/Black/Blue Temperature Sensor (Usually outdoors on a Heat Pump System)
T Varies/Tan/Gray Outdoor Anticipator Reset, Thermistor
X Varies/Black Emergency Heat (Heat Pump) or Common
X2 Varies 2nd stage/emergency heating or indicator lights
L Varies Service Light
U Varies User programmable (usually for humidifier)
K Yellow/Green Combined Y and G
PS Varies Pipe Sensor for two pipe heat/cool systems
V Varies Variable speed (many can function as W2)

Older, mostly deprecated designations:

Terminal code Description
5 / V 24 volt ac supply
4 / M 24 volt HEAT load
6 / blank Not heat to close valve
F Cool fan relay or Fault light
G Heat fan relay
H Heat valve
M Heat Pump compressor
P Heat Pump defrost
R Heat pump reversing valve
VR 24 volt auxiliary heat
Y Auxiliary heat
C Clock power (usually two terminals) or Cool relay
T Transformer common
Z Fan power source for "Auto" connection

Line-voltage thermostats

[edit]

Line voltage thermostats are most commonly used for electric space heaters such as a baseboard heater or a direct-wired electric furnace. If a line voltage thermostat is used, system power (in the United States, 120 or 240 volts) is directly switched by the thermostat. With switching current often exceeding 40 amperes, using a low voltage thermostat on a line voltage circuit will result at least in the failure of the thermostat and possibly a fire. Line voltage thermostats are sometimes used in other applications, such as the control of fan-coil (fan powered from line voltage blowing through a coil of tubing which is either heated or cooled by a larger system) units in large systems using centralized boilers and chillers, or to control circulation pumps in hydronic heating applications.

Some programmable thermostats are available to control line-voltage systems. Baseboard heaters will especially benefit from a programmable thermostat which is capable of continuous control (as are at least some Honeywell models), effectively controlling the heater like a lamp dimmer, and gradually increasing and decreasing heating to ensure an extremely constant room temperature (continuous control rather than relying on the averaging effects of hysteresis). Systems which include a fan (electric furnaces, wall heaters, etc.) must typically use simple on/off controls.

Digital electronic thermostats

[edit]
Residential digital thermostat
Lux Products' Model TX9000TS Touch Screen Thermostat.
Lux Products WIN100 Heating & Cooling Programmable Outlet Thermostat shown with control door closed and open.

Newer digital thermostats have no moving parts to measure temperature and instead rely on thermistors or other semiconductor devices such as a resistance thermometer (resistance temperature detector). Typically one or more regular batteries must be installed to operate it, although some so-called "power stealing" digital thermostats (operated for energy harvesting) use the common 24-volt AC circuits as a power source, but will not operate on thermopile powered "millivolt" circuits used in some furnaces. Each has an LCD screen showing the current temperature, and the current setting. Most also have a clock, and time-of-day and even day-of-week settings for the temperature, used for comfort and energy conservation. Some advanced models have touch screens, or the ability to work with home automation or building automation systems.

Digital thermostats use either a relay or a semiconductor device such as triac to act as a switch to control the HVAC unit. Units with relays will operate millivolt systems, but often make an audible "click" noise when switching on or off.

HVAC systems with the ability to modulate their output can be combined with thermostats that have a built-in PID controller to achieve smoother operation. There are also modern thermostats featuring adaptive algorithms to further improve the inertia prone system behaviour. For instance, setting those up so that the temperature in the morning at 7 a.m. should be 21 °C (69.8 °F), makes sure that at that time the temperature will be 21 °C (69.8 °F), where a conventional thermostat would just start working at that time. The algorithms decide at what time the system should be activated in order to reach the desired temperature at the desired time.[18] Other thermostat used for process/industrial control where on/off control is not suitable the PID control can also makes sure that the temperature is very stable (for instance, by reducing overshoots by fine tuning PID constants for set value (SV)[19] or maintaining temperature in a band by deploying hysteresis control.[20])

Most digital thermostats in common residential use in North America and Europe are programmable thermostats, which will typically provide a 30% energy savings if left with their default programs; adjustments to these defaults may increase or reduce energy savings.[21] The programmable thermostat article provides basic information on the operation, selection and installation of such a thermostat.

Thermostats and HVAC operation

[edit]

Ignition sequences in modern conventional systems

[edit]
Gas
  1. Start draft inducer fan/blower (if the furnace is relatively recent) to create a column of air flowing up the chimney
  2. Heat ignitor or start spark-ignition system
  3. Open gas valve to ignite main burners
  4. Wait (if furnace is relatively recent) until the heat exchanger is at proper operating temperature before starting main blower fan or circulator pump
Oil
Similar to gas, except rather than opening a valve, the furnace will start an oil pump to inject oil into the burner
Electric
The blower fan or circulator pump will be started, and a large electromechanical relay or TRIAC will turn on the heating elements
Coal, grain or pellet
Generally rare today (though grains such as corn, wheat, and barley, or pellets made of wood, bark, or cardboard are increasing in popularity); similar to gas, except rather than opening a valve, the furnace will start a screw to drive coal/grain/pellets into the firebox

With non-zoned (typical residential, one thermostat for the whole house) systems, when the thermostat's R (or Rh) and W terminals are connected, the furnace will go through its start-up procedure and produce heat.

With zoned systems (some residential, many commercial systems — several thermostats controlling different "zones" in the building), the thermostat will cause small electric motors to open valves or dampers and start the furnace or boiler if it is not already running.

Most programmable thermostats will control these systems.

Combination heating/cooling regulation

[edit]

Depending on what is being controlled, a forced-air air conditioning thermostat generally has an external switch for heat/off/cool, and another on/auto to turn the blower fan on constantly or only when heating and cooling are running. Four wires come to the centrally-located thermostat from the main heating/cooling unit (usually located in a closet, basement, or occasionally in the attic): One wire, usually red, supplies 24 volts AC power to the thermostat, while the other three supply control signals from the thermostat, usually white for heat, yellow for cooling, and green to turn on the blower fan. The power is supplied by a transformer, and when the thermostat makes contact between the 24 volt power and one or two of the other wires, a relay back at the heating/cooling unit activates the corresponding heat/fan/cool function of the unit(s).

A thermostat, when set to "cool", will only turn on when the ambient temperature of the surrounding room is above the set temperature. Thus, if the controlled space has a temperature normally above the desired setting when the heating/cooling system is off, it would be wise to keep the thermostat set to "cool", despite what the temperature is outside. On the other hand, if the temperature of the controlled area falls below the desired degree, then it is advisable to turn the thermostat to "heat".

Heat pump regulation

[edit]
Thermostat design

The heat pump is a refrigeration based appliance which reverses refrigerant flow between the indoor and outdoor coils. This is done by energizing a reversing valve (also known as a "4-way" or "change-over" valve). During cooling, the indoor coil is an evaporator removing heat from the indoor air and transferring it to the outdoor coil where it is rejected to the outdoor air. During heating, the outdoor coil becomes the evaporator and heat is removed from the outdoor air and transferred to the indoor air through the indoor coil. The reversing valve, controlled by the thermostat, causes the change-over from heat to cool. Residential heat pump thermostats generally have an "O" terminal to energize the reversing valve in cooling. Some residential and many commercial heat pump thermostats use a "B" terminal to energize the reversing valve in heating. The heating capacity of a heat pump decreases as outdoor temperatures fall. At some outdoor temperature (called the balance point) the ability of the refrigeration system to transfer heat into the building falls below the heating needs of the building. A typical heat pump is fitted with electric heating elements to supplement the refrigeration heat when the outdoor temperature is below this balance point. Operation of the supplemental heat is controlled by a second stage heating contact in the heat pump thermostat. During heating, the outdoor coil is operating at a temperature below the outdoor temperature and condensation on the coil may take place. This condensation may then freeze onto the coil, reducing its heat transfer capacity. Heat pumps therefore have a provision for occasional defrost of the outdoor coil. This is done by reversing the cycle to the cooling mode, shutting off the outdoor fan, and energizing the electric heating elements. The electric heat in defrost mode is needed to keep the system from blowing cold air inside the building. The elements are then used in the "reheat" function. Although the thermostat may indicate the system is in defrost and electric heat is activated, the defrost function is not controlled by the thermostat. Since the heat pump has electric heat elements for supplemental and reheats, the heat pump thermostat provides for use of the electric heat elements should the refrigeration system fail. This function is normally activated by an "E" terminal on the thermostat. When in emergency heat, the thermostat makes no attempt to operate the compressor or outdoor fan.

Thermostat location

[edit]

The thermostat should not be located on an outside wall or where it could be exposed to direct sunlight at any time during the day. It should be located away from the room's cooling or heating vents or device, yet exposed to general airflow from the room(s) to be regulated.[22] An open hallway may be most appropriate for a single zone system, where living rooms and bedrooms are operated as a single zone. If the hallway may be closed by doors from the regulated spaces then these should be left open when the system is in use. If the thermostat is too close to the source controlled then the system will tend to "short a cycle", and numerous starts and stops can be annoying and in some cases shorten equipment life. A multiple zoned system can save considerable energy by regulating individual spaces, allowing unused rooms to vary in temperature by turning off the heating and cooling.

Setback temperature

[edit]

HVAC systems take a long time, usually one to several hours, to cool down or warm up the space from near outdoor conditions in summer or winter. Thus, it is a common practice to set setback temperatures when the space is not occupied (night and/or holidays). On the one hand, compared with maintaining at the original setpoint, substantial energy consumption can be saved.[23] On the other hand, compared with turning off the system completely, it avoids room temperature drifting too much from the comfort zone, thus reducing the time of possible discomfort when the space is again occupied. New thermostats are mostly programmable and include an internal clock that allows this setback feature to be easily incorporated.

Dummy thermostats

[edit]

It has been reported that many thermostats in office buildings are non-functional dummy devices, installed to give tenants' employees an illusion of control.[24][25] These dummy thermostats are in effect a type of placebo button. However, these thermostats are often used to detect the temperature in the zone, even though their controls are disabled. This function is often referred to as "lockout".[26]

See also

[edit]

Notes and references

[edit]
  1. ^ Energy Information Administration, Residential energy consumption survey, U.S. Dept. Energy, Washington, DC, Tech. Rep., 2001.
  2. ^ thermostathub (June 26, 2023). "Easy Home Heating: Get Started with the Danfoss Wireless Thermostat". Thermostat Hub. Retrieved October 23, 2023.
  3. ^ Homod, Raad Z.; Gaeid, Khalaf S.; Dawood, Suroor M.; Hatami, Alireza; Sahari, Khairul S. (August 2020). "Evaluation of energy-saving potential for optimal time response of HVAC control system in smart buildings". Applied Energy. 271: 115255. Bibcode:2020ApEn..27115255H. doi:10.1016/j.apenergy.2020.115255. S2CID 219769422.
  4. ^ Roots, W. K. (1962). "An introduction to the assessment of line-voltage thermostat performance for electric heating applications". Transactions of the American Institute of Electrical Engineers, Part II: Applications and Industry. 81 (3): 176–183. doi:10.1109/TAI.1962.6371813. ISSN 0097-2185. S2CID 51647958.
  5. ^ James E. Brumbaugh, AudelHVAC Fundamentals: Volume 2: Heating System Components, Gas and Oil Burners, and Automatic Controls, John Wiley & Sons, 2004 ISBN 0764542079 pp. 109-119
  6. ^ "Tierie, Gerrit. Cornelis Drebbel. Amsterdam: HJ Paris, 1932" (PDF). Retrieved May 3, 2013.
  7. ^ "An Early History Of Comfort Heating". The NEWS Magazine. Troy, Michigan: BNP Media. November 6, 2001. Retrieved November 2, 2014.
  8. ^ "Thermostat Maker Deploys Climate Control Against Climate Change". America.gov. Archived from the original on April 18, 2009. Retrieved October 3, 2009.
  9. ^ "Johnson Controls Inc. | History". Johnsoncontrols.com. November 7, 2007. Retrieved October 3, 2009.
  10. ^ Falk, Cynthia G. (2012). Barns of New York: Rural Architecture of the Empire State (paperback) (First ed.). Ithaca, New York: Cornell University Press (published May 1, 2012). ISBN 978-0-8014-7780-5. Retrieved November 2, 2014.
  11. ^ "Dr-Fix-It Explains a Common Pneumatic Comfort Control Circuit". dr-fix-it.com. RTWEB. 2005. Archived from the original on December 6, 2017. Retrieved November 2, 2014.
  12. ^ Fehring, T.H., ed., Mechanical Engineering: A Century of Progress, NorCENergy Consultants, LLC, October 10, 1980 - Technology & Engineering, p. 22
  13. ^ "Pneumatic-to-digital devices, systems and methods" (PDF).
  14. ^ Salazar, Diet (October 21, 2019). "Thermostats: Everything You Need to Know". Engineer Warehouse. Retrieved March 12, 2021.
  15. ^ Electrical potentials at and below 24 volts are classed as "Safety Extra-Low Voltage" under most electrical codes when supplied through an isolation transformer.
  16. ^ Sawyer, Doc. "Thermostat Wire Color Codes". dr-fix-it.com. Archived from the original on September 23, 2015. Retrieved March 7, 2015.[1]
  17. ^ Transtronics, Inc. "Thermostat signals and wiring". wiki.xtronics.com. Retrieved March 7, 2015.
  18. ^ Honeywell smart response technology
  19. ^ "Smart PID temperature control". smartpid.com. September 19, 2016. Retrieved October 10, 2018.
  20. ^ "Temperature Controllers Using Hysteresis". panasonic.com. October 18, 2011. Retrieved October 10, 2018.
  21. ^ "Summary of Research Findings From the Programmable Thermostat Market" (PDF). Energy Star. Retrieved March 12, 2021.
  22. ^ KMC Controls. "Room Sensor and Thermostat: Mounting and Maintenance Application Guide" (PDF). Retrieved April 12, 2021.
  23. ^ Moon, Jin Woo; Han, Seung-Hoon (February 1, 2011). "Thermostat strategies impact on energy consumption in residential buildings". Energy and Buildings. 43 (2): 338–346. Bibcode:2011EneBu..43..338M. doi:10.1016/j.enbuild.2010.09.024. ISSN 0378-7788.
  24. ^ Sandberg, Jared (January 15, 2003). "Employees Only Think They Control Thermostat". The Wall Street Journal. Retrieved September 2, 2009.
  25. ^ Katrina C. Arabe (April 11, 2003). ""Dummy" Thermostats Cool Down Tempers, Not Temperatures". Retrieved February 13, 2010.
  26. ^ Example datasheet of current art thermostat, exhibiting lockout functionality : http://cgproducts.johnsoncontrols.com/MET_PDF/12011079.pdf
[edit]

 

Photo
Photo
Photo
View GBP

Frequently Asked Questions

Common signs include inconsistent temperatures throughout your home, unusual noises like rattling or whistling coming from the ducts, and visible damage such as cracks or holes in the ductwork.
If certain rooms have weaker airflow compared to others despite open vents and a functioning HVAC system, it might indicate blockages or leaks in the ductwork.
Excessive dust could signal leaks in the ducts that allow unfiltered air to enter your living spaces, bypassing air filters and reducing indoor air quality.
Yes, damaged or leaking ducts cause your HVAC system to work harder than necessary, leading to higher energy consumption and increased utility costs.
Mold growth around vents suggests moisture issues within the ducts, which might stem from leaks or inadequate insulation needing professional attention.