Air conditioning units are vital for maintaining comfort during sweltering summer months. However, it's not uncommon for these units to experience freeze-ups, leading to inefficiencies and sometimes even damage. Understanding the common causes of AC unit freeze-ups is essential for homeowners and technicians alike in order to prevent this issue and ensure optimal performance.
One prevalent cause of AC unit freeze-ups is restricted airflow. Air conditioners rely on a continuous flow of air over the evaporator coils to function correctly. Keeping your system efficient starts with HVAC repair services before summer or winter puts extra strain on your system.. When airflow is impeded-often due to dirty filters, blocked vents, or closed registers-the coils can become too cold and eventually freeze. Regularly changing air filters and ensuring that all vents are clear from obstructions can significantly reduce the risk of this problem.
Another significant factor contributing to freezing is low refrigerant levels. Refrigerant plays a critical role in absorbing heat from indoor air; if there's a leak or the refrigerant charge is insufficient, the pressure inside the system drops. This drop in pressure causes the temperature around the evaporator coil to fall below freezing, leading to ice formation. Addressing refrigerant issues typically requires professional attention since it involves handling chemicals that require proper care and equipment.
AC units may also freeze up due to malfunctioning thermostats or faulty blower fans. A thermostat that's incorrectly calibrated might signal incorrect temperatures, causing the system to run when it shouldn't. Similarly, if a blower fan isn't operating at its full capacity, it won't be able to move enough air across the evaporator coil. Ensuring that both components are functioning correctly through regular maintenance checks can help mitigate these risks.
Additionally, environmental factors such as outside temperatures dropping too low overnight can also result in a frozen unit. AC units are designed primarily for cooling rather than heating; thus, they're not equipped to handle lower temperatures effectively without specific adjustments or modifications.
Preventative measures play an essential role in avoiding AC unit freeze-ups. In addition to routine maintenance like changing filters and checking refrigerant levels, it's important to schedule annual inspections by HVAC professionals who can diagnose potential issues before they escalate into larger problems.
In conclusion, while AC unit freeze-ups can be frustrating and inconvenient, understanding their common causes allows homeowners and service providers to take proactive steps in preventing them. By ensuring adequate airflow, maintaining appropriate refrigerant levels, keeping thermostats properly calibrated, and conducting regular professional inspections, one can enhance their air conditioner's efficiency while extending its lifespan-ensuring cool comfort even during peak heat waves.
Air conditioning units are essential for maintaining comfortable indoor temperatures, especially during the sweltering summer months. However, many homeowners encounter a perplexing issue: their AC units freeze up. While there are several reasons why this might happen, one often overlooked cause is the impact of dirty air filters. Understanding how these filters affect your AC's performance can help in preventing this frustrating problem.
Air filters are critical components of any HVAC system. They trap dust, pollen, and other airborne particles, ensuring that the air circulated throughout your home remains clean and breathable. Over time, however, these filters can become clogged with dirt and debris. When an air filter is dirty or clogged, it restricts airflow into the unit. This restriction forces the AC to work harder to pull in enough air to cool down your home.
The reduced airflow caused by a dirty filter has several negative consequences on an AC unit's performance. Firstly, it puts undue strain on the blower motor as it struggles to draw in sufficient air. This extra effort not only increases energy consumption but also accelerates wear and tear on the system's components.
More critically, inadequate airflow over the evaporator coil can lead to freezing issues. The evaporator coil is responsible for absorbing heat from your home's air; without sufficient warm air flowing over it due to a restricted filter, the coil's temperature drops too low. Moisture in the surrounding air then freezes upon contact with this overly cold surface, gradually leading to ice formation on the coil itself.
As ice accumulates on the evaporator coil, it further impedes airflow and exacerbates cooling problems. In severe cases, this can result in complete blockage of airflow through the system or even damage vital components like compressor failure due to liquid refrigerant returning back into it-a condition known as "liquid slugging."
Preventing an AC unit from freezing up starts with regular maintenance of its air filters. It is recommended that homeowners check their filters at least once a month and replace them every 1-3 months depending on usage and environmental factors like pet dander or high pollen levels.
In addition to keeping filters clean or replacing them regularly, ensuring that vents are unobstructed by furniture or draperies will promote better circulation throughout your space-further safeguarding against freezing issues.
Dirty air filters might seem like minor components within complex HVAC systems; however, they play an outsized role in determining overall efficiency and reliability of an AC unit's operation-especially when it comes to avoiding costly freeze-ups during peak seasons when you need cooling most desperately!
By staying vigilant about maintaining clean air filters along with routine professional inspections every year (or more frequently if necessary), you can ensure optimal performance from your AC unit while extending its lifespan significantly-and enjoying uninterrupted comfort regardless of what Mother Nature throws outside!
Air conditioning units are essential for maintaining comfort in our homes, especially during the sweltering heat of summer. However, like any other mechanical system, air conditioners require proper maintenance to function efficiently. One common issue that many homeowners face is their AC unit freezing up. While there can be several reasons for this problem, maintaining the proper refrigerant levels is crucial in preventing it.
Refrigerants play a pivotal role in the cooling process of an air conditioning system. They absorb heat from indoor air and release it outside, thus cooling your home. For this process to occur seamlessly, the refrigerant must be at the correct level.
When refrigerant levels are too low, usually due to leaks or improper installation, the pressure within the system drops. This decrease in pressure causes the evaporator coil to become extremely cold and eventually freeze over. As a result, airflow is restricted or completely blocked by ice build-up on the coils. This not only reduces cooling efficiency but also puts additional strain on the compressor as it struggles to maintain desired temperatures.
Conversely, overcharging an air conditioner with refrigerant can also lead to freezing issues. Excessive refrigerant increases pressure within the system beyond optimal levels; this imbalance disrupts normal functioning and can cause components like compressors or expansion valves to malfunction. Moreover, overcharging often leads to increased energy consumption and potential damage over time.
To prevent these issues from arising due simply incorrect refrigerant levels management – regular maintenance checks by certified HVAC professionals are vital! These experts will carefully measure current conditions ensuring everything runs smoothly under manufacturer specifications without risking costly breakdowns later down line due negligence today!
In conclusion: Properly maintained systems utilizing correct amounts coolant not only ensure maximum efficiency but also prolong lifespan preventing unnecessary headaches associated unexpected malfunctions caused neglectful practices such ignoring routine inspections altogether! So next time you schedule service appointment make sure emphasize importance checking those all-important numbers keeping cool calm collected when mercury rises highest!
Air conditioning units are vital in providing comfort during hot weather, yet they can sometimes freeze up, leading to inefficiency and potential damage. One key factor that plays a significant role in preventing these freeze-ups is the thermostat setting. Understanding the interplay between thermostat settings and AC unit performance is essential for maintaining an efficient system and avoiding costly repairs.
At the heart of an air conditioning system's functionality is the regulation of temperature within a given space. The thermostat acts as the control center, dictating when the AC unit should cycle on and off to maintain desired indoor temperatures. However, improper thermostat settings can lead to conditions that encourage freeze-ups. For instance, setting the temperature too low might cause the evaporator coil to become excessively cold. When this happens, humidity in the air can condense on the coil and subsequently freeze if it remains below freezing temperatures for extended periods.
To prevent such scenarios, it is crucial for users to set their thermostats at a reasonable level. Most experts recommend keeping your home's temperature around 72-78 degrees Fahrenheit during summer months. This range not only ensures personal comfort but also allows your AC unit to operate efficiently without overburdening its components.
Moreover, modern thermostats often come with programmable features that allow users to set different temperatures for various times of day or days of the week. Utilizing these features can optimize energy use while ensuring that your AC unit has adequate downtime to defrost naturally if needed. For example, raising the thermostat setting by a few degrees during nighttime or when no one is home can reduce strain on the system and minimize risk of freeze-ups.
In addition to mindful thermostat adjustments, regular maintenance checks are paramount in preventing air conditioner freezing issues. Ensuring proper airflow by cleaning filters and inspecting ducts complements appropriate thermostat settings by allowing cool air to circulate freely throughout your home.
In conclusion, while several factors contribute to why some AC units may freeze up, such as refrigerant levels or airflow issues, thermostat settings play a critical role in prevention strategies. By understanding how your thermostat interacts with your air conditioning system and making informed adjustments based on expert recommendations, you can significantly reduce instances of freeze-ups while promoting longevity and efficiency in your cooling equipment.
Air conditioning units are vital for maintaining comfort in our homes and workplaces, especially during the sweltering summer months. However, many homeowners have encountered the perplexing issue of their AC units freezing up. This problem not only hampers the cooling efficiency but can also lead to significant damage if left unresolved. One effective way to prevent such issues is by investing in annual HVAC maintenance checks.
The benefits of regular HVAC maintenance extend beyond just preventing your air conditioning unit from freezing up. At the heart of this routine care is the assurance that every component of your system is operating optimally. A professional technician will inspect and clean coils, check refrigerant levels, and ensure that the airflow is unobstructed. These measures prevent common causes of freezing, such as restricted airflow or low refrigerant levels.
When an AC unit freezes, it's often due to a combination of factors like dirty filters or blocked vents that restrict airflow across the evaporator coil. Without sufficient warm air passing over it, the coil gets too cold and moisture freezes on it. During an annual check-up, technicians replace or clean filters and clear any blockages in the ductwork, ensuring that air circulates freely throughout the system.
Another critical aspect covered in these maintenance visits is checking refrigerant levels. Insufficient refrigerant can cause a drop in pressure inside the evaporator coil, leading it to freeze over time. Regular maintenance ensures that any leaks are detected early, allowing for timely recharging of refrigerants to optimal levels.
Moreover, annual HVAC checks include inspecting electrical connections and components for wear and tear. Faulty parts can lead to intermittent operation issues that might contribute to an AC unit's inefficiency or malfunctioning-possibly even causing it to freeze under certain conditions.
By scheduling regular maintenance checks, homeowners gain peace of mind knowing their systems are less likely to suffer unexpected breakdowns when they're needed most. Preventive care helps prolong the life of an AC unit by addressing minor issues before they escalate into costly repairs or replacements.
In conclusion, while frozen AC units can be a frustrating problem, they are often preventable through routine annual HVAC maintenance checks. This proactive approach not only ensures that your cooling system operates efficiently but also saves time and money by minimizing emergency repair situations. Ultimately, investing in regular maintenance translates into consistent comfort during hot weather and extends the lifespan of your valuable home appliance.
Air conditioning units are indispensable for maintaining comfort during scorching summers, but sometimes they can leave homeowners in a state of bewilderment when they unexpectedly freeze up. This perplexing phenomenon can be both inconvenient and costly if not addressed promptly. However, by understanding why AC units freeze and implementing regular maintenance practices, homeowners can prevent these issues and ensure their cooling systems operate smoothly.
AC units typically freeze up due to a combination of factors that impede the normal flow of air or refrigerant through the system. One common cause is restricted airflow, often resulting from dirty or clogged air filters. When airflow is obstructed, it causes the evaporator coil to get too cold, leading to ice formation. Similarly, low refrigerant levels or leaks in the system can result in insufficient heat absorption by the refrigerant, causing the coils to freeze.
Another contributing factor is malfunctioning thermostats or sensors that fail to accurately regulate temperature settings. If an AC unit runs constantly without cycling off appropriately, it might lead to overcooling and eventual freezing. Additionally, environmental conditions such as excessively low outdoor temperatures can also induce freezing if the unit operates when it should ideally be turned off.
To prevent these frustrating freeze-ups, regular maintenance plays a crucial role. First and foremost, changing or cleaning air filters on a routine basis ensures proper airflow throughout the system. This simple step not only prevents freezing but also enhances overall efficiency by allowing the unit to cool effectively without undue strain.
Moreover, scheduling professional inspections at least once a year helps identify potential issues before they escalate into major problems.
Homeowners should also be mindful of thermostat settings and avoid setting them too low in an attempt to cool rooms quickly. Allowing the AC unit to cycle on and off prevents excessive wear while maintaining comfort indoors.
Lastly, during colder months when AC use may be minimal or unnecessary altogether, it is advisable to turn off outdoor units completely if temperatures drop significantly. This precautionary measure prevents unexpected operations that could lead to freezing damage under unsuitable conditions.
In conclusion, understanding why some AC units freeze up empowers homeowners with knowledge essential for prevention through regular maintenance practices-changing filters regularly; scheduling professional inspections; monitoring thermostat settings; turning off outdoor units during cold weather-all contribute towards extending equipment lifespan while ensuring uninterrupted cooling comfort throughout hot seasons ahead!
Part of a series on |
Sustainable energy |
---|
![]() |
Geothermal heating is the direct use of geothermal energy for some heating applications. Humans have taken advantage of geothermal heat this way since the Paleolithic era. Approximately seventy countries made direct use of a total of 270 PJ of geothermal heating in 2004. As of 2007, 28 GW of geothermal heating capacity is installed around the world, satisfying 0.07% of global primary energy consumption.[1] Thermal efficiency is high since no energy conversion is needed, but capacity factors tend to be low (around 20%) since the heat is mostly needed in the winter.
Geothermal energy originates from the heat retained within the Earth since the original formation of the planet, from radioactive decay of minerals, and from solar energy absorbed at the surface.[2] Most high temperature geothermal heat is harvested in regions close to tectonic plate boundaries where volcanic activity rises close to the surface of the Earth. In these areas, ground and groundwater can be found with temperatures higher than the target temperature of the application. However, even cold ground contains heat. Below 6 metres (20 ft), the undisturbed ground temperature is consistently at the mean annual air temperature,[3] and this heat can be extracted with a ground source heat pump.
Country | Production PJ/yr |
Capacity GW |
Capacity factor |
Dominant applications |
---|---|---|---|---|
China | 45.38 | 3.69 | 39% | bathing |
Sweden | 43.2 | 4.2 | 33% | heat pumps |
USA | 31.24 | 7.82 | 13% | heat pumps |
Turkey | 24.84 | 1.5 | 53% | district heating |
Iceland | 24.5 | 1.84 | 42% | district heating |
Japan | 10.3 | 0.82 | 40% | bathing (onsens) |
Hungary | 7.94 | 0.69 | 36% | spas/greenhouses |
Italy | 7.55 | 0.61 | 39% | spas/space heating |
New Zealand | 7.09 | 0.31 | 73% | industrial uses |
63 others | 71 | 6.8 | ||
Total | 273 | 28 | 31% | space heating |
Category | GWh/year |
---|---|
Geothermal heat pumps | 90,293 |
Bathing and swimming | 33,164 |
Space heating | 24,508 |
Greenhouse heating | 7,407 |
Aquaculture pond heating | 3,322 |
Industrial uses | 2,904 |
Cooling/snow melting | 722 |
Agriculture drying | 564 |
Others | 403 |
Total | 163,287 |
There are a wide variety of applications for cheap geothermal heat including heating of houses, greenhouses, bathing and swimming or industrial uses. Most applications use geothermal in the form of hot fluids between 50 °C (122 °F) and 150 °C (302 °F). The suitable temperature varies for the different applications. For direct use of geothermal heat, the temperature range for the agricultural sector lies between 25 °C (77 °F) and 90 °C (194 °F), for space heating lies between 50 °C (122 °F) to 100 °C (212 °F).[4] Heat pipes extend the temperature range down to 5 °C (41 °F) as they extract and "amplify" the heat. Geothermal heat exceeding 150 °C (302 °F) is typically used for geothermal power generation.[6]
In 2004 more than half of direct geothermal heat was used for space heating, and a third was used for spas.[1] The remainder was used for a variety of industrial processes, desalination, domestic hot water, and agricultural applications. The cities of Reykjavík and Akureyri pipe hot water from geothermal plants under roads and pavements to melt snow. Geothermal desalination has been demonstrated.
Geothermal systems tend to benefit from economies of scale, so space heating power is often distributed to multiple buildings, sometimes whole communities. This technique, long practiced throughout the world in locations such as Reykjavík, Iceland;[7] Boise, Idaho;[8] and Klamath Falls, Oregon;[9] is known as district heating.[10]
In Europe alone 280 geothermal district heating plants were in operation in 2016 according to the European Geothermal Energy Council (EGEC) with a total capacity of approximately 4.9 GWth.[11]
Some parts of the world, including substantial portions of the western USA, are underlain by relatively shallow geothermal resources.[12] Similar conditions exist in Iceland, parts of Japan, and other geothermal hot spots around the world. In these areas, water or steam may be captured from natural hot springs and piped directly into radiators or heat exchangers. Alternatively, the heat may come from waste heat supplied by co-generation from a geothermal electrical plant or from deep wells into hot aquifers. Direct geothermal heating is far more efficient than geothermal electricity generation and has less demanding temperature requirements, so it is viable over a large geographical range. If the shallow ground is hot but dry, air or water may be circulated through earth tubes or downhole heat exchangers which act as heat exchangers with the ground.
Steam under pressure from deep geothermal resources is also used to generate electricity from geothermal power. The Iceland Deep Drilling Project struck a pocket of magma at 2,100m. A cemented steelcase was constructed in the hole with a perforation at the bottom close to the magma. The high temperatures and pressure of the magma steam were used to generate 36MW of electricity, making IDDP-1 the world's first magma-enhanced geothermal system.[13]
In areas where the shallow ground is too cold to provide comfort directly, it is still warmer than the winter air. The thermal inertia of the shallow ground retains solar energy accumulated in the summertime, and seasonal variations in ground temperature disappear completely below 10m of depth. That heat can be extracted with a geothermal heat pump more efficiently than it can be generated by conventional furnaces.[10] Geothermal heat pumps are economically viable essentially anywhere in the world.
In theory, geothermal energy (usually cooling) can also be extracted from existing infrastructure, such as municipal water pipes.[14]
In regions without any high temperature geothermal resources, a ground-source heat pump (GSHP) can provide space heating and space cooling. Like a refrigerator or air conditioner, these systems use a heat pump to force the transfer of heat from the ground to the building. Heat can be extracted from any source, no matter how cold, but a warmer source allows higher efficiency. A ground-source heat pump uses the shallow ground or ground water (typically starting at 10–12 °C or 50–54 °F) as a source of heat, thus taking advantage of its seasonally moderate temperatures.[15] In contrast, an air source heat pump draws heat from the air (colder outside air) and thus requires more energy.
GSHPs circulate a carrier fluid (usually a mixture of water and small amounts of antifreeze) through closed pipe loops buried in the ground. Single-home systems can be "vertical loop field" systems with bore holes 50–400 feet (15–120 m) deep or,[16] if adequate land is available for extensive trenches, a "horizontal loop field" is installed approximately six feet subsurface. As the fluid circulates underground it absorbs heat from the ground and, on its return, the warmed fluid passes through the heat pump which uses electricity to extract heat from the fluid. The re-chilled fluid is sent back into the ground thus continuing the cycle. The heat extracted and that generated by the heat pump appliance as a byproduct is used to heat the house. The addition of the ground heating loop in the energy equation means that significantly more heat can be transferred to a building than if electricity alone had been used directly for heating.
Switching the direction of heat flow, the same system can be used to circulate the cooled water through the house for cooling in the summer months. The heat is exhausted to the relatively cooler ground (or groundwater) rather than delivering it to the hot outside air as an air conditioner does. As a result, the heat is pumped across a larger temperature difference and this leads to higher efficiency and lower energy use.[15]
This technology makes ground source heating economically viable in any geographical location. In 2004, an estimated million ground-source heat pumps with a total capacity of 15 GW extracted 88 PJ of heat energy for space heating. Global ground-source heat pump capacity is growing by 10% annually.[1]
Hot springs have been used for bathing at least since Paleolithic times.[17] The oldest known spa is a stone pool on China's Mount Li built in the Qin dynasty in the 3rd century BC, at the same site where the Huaqing Chi palace was later built. Geothermal energy supplied channeled district heating for baths and houses in Pompeii around 0 AD.[18] In the first century AD, Romans conquered Aquae Sulis in England and used the hot springs there to feed public baths and underfloor heating.[19] The admission fees for these baths probably represents the first commercial use of geothermal power. A 1,000-year-old hot tub has been located in Iceland, where it was built by one of the island's original settlers.[20] The world's oldest working geothermal district heating system in Chaudes-Aigues, France, has been operating since the 14th century.[4] The earliest industrial exploitation began in 1827 with the use of geyser steam to extract boric acid from volcanic mud in Larderello, Italy.
In 1892, America's first district heating system in Boise, Idaho, was powered directly by geothermal energy, and was soon copied in Klamath Falls, Oregon in 1900. A deep geothermal well was used to heat greenhouses in Boise in 1926, and geysers were used to heat greenhouses in Iceland and Tuscany at about the same time.[21] Charlie Lieb developed the first downhole heat exchanger in 1930 to heat his house. Steam and hot water from the geysers began to be used to heat homes in Iceland in 1943.
By this time, Lord Kelvin had already invented the heat pump in 1852, and Heinrich Zoelly had patented the idea of using it to draw heat from the ground in 1912.[22] But it was not until the late 1940s that the geothermal heat pump was successfully implemented. The earliest one was probably Robert C. Webber's home-made 2.2 kW direct-exchange system, but sources disagree as to the exact timeline of his invention.[22] J. Donald Kroeker designed the first commercial geothermal heat pump to heat the Commonwealth Building (Portland, Oregon) and demonstrated it in 1946.[23][24] Professor Carl Nielsen of Ohio State University built the first residential open loop version in his home in 1948.[25] The technology became popular in Sweden as a result of the 1973 oil crisis, and has been growing slowly in worldwide acceptance since then. The 1979 development of polybutylene pipe greatly augmented the heat pump's economic viability.[23] Since 2000, a compelling body of research has been dedicated to numerically evidence the advantages and efficiency of using CO2, alternative to water, as heat transmission fluid for geothermal energy recovery from enhanced geothermal systems (EGS) where the permeability of the underground source is enhanced by hydrofracturing.[26][27] As of 2004, there are over one million geothermal heat pumps installed worldwide providing 12 GW of thermal capacity.[28] Each year, about 80,000 units are installed in the US and 27,000 in Sweden.[28]
Geothermal energy is a type of renewable energy that encourages conservation of natural resources. According to the US Environmental Protection Agency, geo-exchange systems save homeowners 30–70 percent in heating costs, and 20–50 percent in cooling costs, compared to conventional systems.[29] Geo-exchange systems also save money because they require much less maintenance. In addition to being highly reliable they are built to last for decades.
Some utilities, such as Kansas City Power and Light, offer special, lower winter rates for geothermal customers, offering even more savings.[15]
In geothermal heating projects the underground is penetrated by trenches or drillholes. As with all underground work, projects may cause problems if the geology of the area is poorly understood.
In the spring of 2007 an exploratory geothermal drilling operation was conducted to provide geothermal heat to the town hall of Staufen im Breisgau. After initially sinking a few millimeters, a process called subsidence,[30] the city center has started to rise gradually[31] causing considerable damage to buildings in the city center, affecting numerous historic houses including the town hall. It is hypothesized that the drilling perforated an anhydrite layer bringing high-pressure groundwater to come into contact with the anhydrite, which then began to expand. Currently no end to the rising process is in sight.[32][33][34] Data from the TerraSAR-X radar satellite before and after the changes confirmed the localised nature of the situation:
A geochemical process called anhydrite swelling has been confirmed as the cause of these uplifts. This is a transformation of the mineral anhydrite (anhydrous calcium sulphate) into gypsum (hydrous calcium sulphate). A pre-condition for this transformation is that the anhydrite is in contact with water, which is then stored in its crystalline structure.[35] There are other sources of potential risks, i.e.: cave enlargement or worsening of stability conditions, quality or quantity degradation of groundwater resources, Specific hazard worsening in the case of landslide-prone areas, worsening of rocky mechanical characteristics, soil and water pollution (i.e. due to antifreeze additives or polluting constructive and boring material).[36] The design defined on the base of site-specific geological, hydrogeological and environmental knowledge prevent all these potential risks.
During Roman times, warm water was circulated through open trenches to provide heating for buildings and baths in Pompeii.
Part of a series on |
Pollution |
---|
![]() |
Indoor air quality (IAQ) is the air quality within buildings and structures. Poor indoor air quality due to indoor air pollution is known to affect the health, comfort, and well-being of building occupants. It has also been linked to sick building syndrome, respiratory issues, reduced productivity, and impaired learning in schools. Common pollutants of indoor air include: secondhand tobacco smoke, air pollutants from indoor combustion, radon, molds and other allergens, carbon monoxide, volatile organic compounds, legionella and other bacteria, asbestos fibers, carbon dioxide,[1] ozone and particulates.
Source control, filtration, and the use of ventilation to dilute contaminants are the primary methods for improving indoor air quality. Although ventilation is an integral component of maintaining good indoor air quality, it may not be satisfactory alone.[2] In scenarios where outdoor pollution would deteriorate indoor air quality, other treatment devices such as filtration may also be necessary.[3]
IAQ is evaluated through collection of air samples, monitoring human exposure to pollutants, analysis of building surfaces, and computer modeling of air flow inside buildings. IAQ is part of indoor environmental quality (IEQ), along with other factors that exert an influence on physical and psychological aspects of life indoors (e.g., lighting, visual quality, acoustics, and thermal comfort).[4]
Indoor air pollution is a major health hazard in developing countries and is commonly referred to as "household air pollution" in that context.[5] It is mostly relating to cooking and heating methods by burning biomass fuel, in the form of wood, charcoal, dung, and crop residue, in indoor environments that lack proper ventilation. Millions of people, primarily women and children, face serious health risks. In total, about three billion people in developing countries are affected by this problem. The World Health Organization (WHO) estimates that cooking-related indoor air pollution causes 3.8 million annual deaths.[6] The Global Burden of Disease study estimated the number of deaths in 2017 at 1.6 million.[7]
For health reasons it is crucial to breathe clean air, free from chemicals and toxicants as much as possible. It is estimated that humans spend approximately 90% of their lifetime indoors[8] and that indoor air pollution in some places can be much worse than that of the ambient air.[9][10]
Various factors contribute to high concentrations of pollutants indoors, ranging from influx of pollutants from external sources, off-gassing by furniture, furnishings including carpets, indoor activities (cooking, cleaning, painting, smoking, etc. in homes to using office equipment in offices), thermal comfort parameters such as temperature, humidity, airflow and physio-chemical properties of the indoor air.[citation needed] Air pollutants can enter a building in many ways, including through open doors or windows. Poorly maintained air conditioners/ventilation systems can harbor mold, bacteria, and other contaminants, which are then circulated throughout indoor spaces, contributing to respiratory problems and allergies.
There have been many debates among indoor air quality specialists about the proper definition of indoor air quality and specifically what constitutes "acceptable" indoor air quality.
IAQ is significant for human health as humans spend a large proportion of their time in indoor environments. Americans and Europeans on average spend approximately 90% of their time indoors.[11][12]
The World Health Organization (WHO) estimates that 3.2 million people die prematurely every year from illnesses attributed to indoor air pollution caused by indoor cooking, with over 237 thousand of these being children under 5. These include around an eighth of all global ischaemic heart disease, stroke, and lung cancer deaths. Overall the WHO estimated that poor indoor air quality resulted in the loss of 86 million healthy life years in 2019.[13]
Studies in the UK and Europe show exposure to indoor air pollutants, chemicals and biological contamination can irritate the upper airway system, trigger or exacerbate asthma and other respiratory or cardiovascular conditions, and may even have carcinogenic effects.[14][15][16][17][18][19]
Poor indoor air quality can cause sick building syndrome. Symptoms include burning of the eyes, scratchy throat, blocked nose, and headaches.[20]
Indoor combustion, such as for cooking or heating, is a major cause of indoor air pollution and causes significant health harms and premature deaths. Hydrocarbon fires cause air pollution. Pollution is caused by both biomass and fossil fuels of various types, but some forms of fuels are more harmful than others.
Indoor fire can produce black carbon particles, nitrogen oxides, sulfur oxides, and mercury compounds, among other emissions.[21] Around 3 billion people cook over open fires or on rudimentary cook stoves. Cooking fuels are coal, wood, animal dung, and crop residues.[22] IAQ is a particular concern in low and middle-income countries where such practices are common.[23]
Cooking using natural gas (also called fossil gas, methane gas or simply gas) is associated with poorer indoor air quality. Combustion of gas produces nitrogen dioxide and carbon monixide, and can lead to increased concentrations of nitrogen dioxide throughout the home environment which is linked to respiratory issues and diseases.[24][25]
One of the most acutely toxic indoor air contaminants is carbon monoxide (CO), a colourless and odourless gas that is a by-product of incomplete combustion. Carbon monoxide may be emitted from tobacco smoke and generated from malfunctioning fuel burning stoves (wood, kerosene, natural gas, propane) and fuel burning heating systems (wood, oil, natural gas) and from blocked flues connected to these appliances.[26] In developed countries the main sources of indoor CO emission come from cooking and heating devices that burn fossil fuels and are faulty, incorrectly installed or poorly maintained.[27] Appliance malfunction may be due to faulty installation or lack of maintenance and proper use.[26] In low- and middle-income countries the most common sources of CO in homes are burning biomass fuels and cigarette smoke.[27]
Health effects of CO poisoning may be acute or chronic and can occur unintentionally or intentionally (self-harm). By depriving the brain of oxygen, acute exposure to carbon monoxide may have effects on the neurological system (headache, nausea, dizziness, alteration in consciousness and subjective weakness), the cardiovascular and respiratory systems (myocardial infarction, shortness of breath, or rapid breathing, respiratory failure). Acute exposure can also lead to long-term neurological effects such as cognitive and behavioural changes. Severe CO poisoning may lead to unconsciousness, coma and death. Chronic exposure to low concentrations of carbon monoxide may lead to lethargy, headaches, nausea, flu-like symptoms and neuropsychological and cardiovascular issues.[28][26]
The WHO recommended levels of indoor CO exposure in 24 hours is 4 mg/m3.[29] Acute exposure should not exceed 10 mg/m3 in 8 hours, 35 mg/m3 in one hour and 100 mg/m3 in 15 minutes.[27]
Secondhand smoke is tobacco smoke which affects people other than the 'active' smoker. It is made up of the exhaled smoke (15%) and mostly of smoke coming from the burning end of the cigarette, known as sidestream smoke (85%).[30]
Secondhand smoke contains more than 7000 chemicals, of which hundreds are harmful to health.[30] Secondhand tobacco smoke includes both a gaseous and a particulate materials which, with particular hazards arising from levels of carbon monoxide and very small particulates (fine particulate matter, especially PM2.5 and PM10) which get into the bronchioles and alveoles in the lung.[31] Inhaling secondhand smoke on multiple occasions can cause asthma, pneumonia, lung cancer, and sudden infant death syndrome, among other conditions.[32]
Thirdhand smoke (THS) refers to chemicals that settle on objects and bodies indoors after smoking. Exposure to thirdhand smoke can happen even after the actual cigarette smoke is not present anymore and affect those entering the indoor environment much later. Toxic substances of THS can react with other chemicals in the air and produce new toxic chemicals that are otherwise not present in cigarettes.[33]
The only certain method to improve indoor air quality as regards secondhand smoke is to eliminate smoking indoors.[34] Indoor e-cigarette use also increases home particulate matter concentrations.[35]
Atmospheric particulate matter, also known as particulates, can be found indoors and can affect the health of occupants. Indoor particulate matter can come from different indoor sources or be created as secondary aerosols through indoor gas-to-particle reactions. They can also be outdoor particles that enter indoors. These indoor particles vary widely in size, ranging from nanomet (nanoparticles/ultrafine particles emitted from combustion sources) to micromet (resuspensed dust).[36] Particulate matter can also be produced through cooking activities. Frying produces higher concentrations than boiling or grilling and cooking meat produces higher concentrations than cooking vegetables.[37] Preparing a Thanksgiving dinner can produce very high concentrations of particulate matter, exceeding 300 μg/m3.[38]
Particulates can penetrate deep into the lungs and brain from blood streams, causing health problems such as heart disease, lung disease, cancer and preterm birth.[39]
Volatile organic compounds (VOCs) include a variety of chemicals, some of which may have short- and long-term adverse health effects. There are numerous sources of VOCs indoors, which means that their concentrations are consistently higher indoors (up to ten times higher) than outdoors.[40] Some VOCs are emitted directly indoors, and some are formed through the subsequent chemical reactions that can occur in the gas-phase, or on surfaces.[41][42] VOCs presenting health hazards include benzene, formaldehyde, tetrachloroethylene and trichloroethylene.[43]
VOCs are emitted by thousands of indoor products. Examples include: paints, varnishes, waxes and lacquers, paint strippers, cleaning and personal care products, pesticides, building materials and furnishings, office equipment such as copiers and printers, correction fluids and carbonless copy paper, graphics and craft materials including glues and adhesives, permanent markers, and photographic solutions.[44] Chlorinated drinking water releases chloroform when hot water is used in the home. Benzene is emitted from fuel stored in attached garages.
Human activities such as cooking and cleaning can also emit VOCs.[45][46] Cooking can release long-chain aldehydes and alkanes when oil is heated and terpenes can be released when spices are prepared and/or cooked.[45] Leaks of natural gas from cooking appliances have been linked to elevated levels of VOCs including benzene in homes in the USA.[47] Cleaning products contain a range of VOCs, including monoterpenes, sesquiterpenes, alcohols and esters. Once released into the air, VOCs can undergo reactions with ozone and hydroxyl radicals to produce other VOCs, such as formaldehyde.[46]
Health effects include eye, nose, and throat irritation; headaches, loss of coordination, nausea; and damage to the liver, kidney, and central nervous system.[48]
Testing emissions from building materials used indoors has become increasingly common for floor coverings, paints, and many other important indoor building materials and finishes.[49] Indoor materials such as gypsum boards or carpet act as VOC 'sinks', by trapping VOC vapors for extended periods of time, and releasing them by outgassing. The VOCs can also undergo transformation at the surface through interaction with ozone.[42] In both cases, these delayed emissions can result in chronic and low-level exposures to VOCs.[50]
Several initiatives aim to reduce indoor air contamination by limiting VOC emissions from products. There are regulations in France and in Germany, and numerous voluntary ecolabels and rating systems containing low VOC emissions criteria such as EMICODE,[51] M1,[52] Blue Angel[53] and Indoor Air Comfort[54] in Europe, as well as California Standard CDPH Section 01350[55] and several others in the US. Due to these initiatives an increasing number of low-emitting products became available to purchase.
At least 18 microbial VOCs (MVOCs) have been characterised[56][57] including 1-octen-3-ol (mushroom alcohol), 3-Methylfuran, 2-pentanol, 2-hexanone, 2-heptanone, 3-octanone, 3-octanol, 2-octen-1-ol, 1-octene, 2-pentanone, 2-nonanone, borneol, geosmin, 1-butanol, 3-methyl-1-butanol, 3-methyl-2-butanol, and thujopsene. The last four are products of Stachybotrys chartarum, which has been linked with sick building syndrome.[56]
Many common building materials used before 1975 contain asbestos, such as some floor tiles, ceiling tiles, shingles, fireproofing, heating systems, pipe wrap, taping muds, mastics, and other insulation materials. Normally, significant releases of asbestos fiber do not occur unless the building materials are disturbed, such as by cutting, sanding, drilling, or building remodelling. Removal of asbestos-containing materials is not always optimal because the fibers can be spread into the air during the removal process. A management program for intact asbestos-containing materials is often recommended instead.
When asbestos-containing material is damaged or disintegrates, microscopic fibers are dispersed into the air. Inhalation of asbestos fibers over long exposure times is associated with increased incidence of lung cancer, mesothelioma, and asbestosis. The risk of lung cancer from inhaling asbestos fibers is significantly greater for smokers. The symptoms of disease do not usually appear until about 20 to 30 years after the first exposure to asbestos.
Although all asbestos is hazardous, products that are friable, e.g. sprayed coatings and insulation, pose a significantly higher hazard as they are more likely to release fibers to the air.[58]
![]() |
Microplastic is a type of airborne particulates and is found to prevail in air.[59][60][61][62] A 2017 study found indoor airborne microfiber concentrations between 1.0 and 60.0 microfibers per cubic meter (33% of which were found to be microplastics).[63] Airborne microplastic dust can be produced during renovation, building, bridge and road reconstruction projects[64] and the use of power tools.[65]
Indoors ozone (O3) is produced by certain high-voltage electric devices (such as air ionizers), and as a by-product of other types of pollution. It appears in lower concentrations indoors than outdoors, usually at 0.2-0.7 of the outdoor concentration.[66] Typically, most ozone is lost to surface reactions indoors, rather than to reactions in air, due to the large surface to volume ratios found indoors.[67]
Outdoor air used for ventilation may have sufficient ozone to react with common indoor pollutants as well as skin oils and other common indoor air chemicals or surfaces. Particular concern is warranted when using "green" cleaning products based on citrus or terpene extracts, because these chemicals react very quickly with ozone to form toxic and irritating chemicals[46] as well as fine and ultrafine particles.[68] Ventilation with outdoor air containing elevated ozone concentrations may complicate remediation attempts.[69]
The WHO standard for ozone concentration is 60 μg/m3 for long-term exposure and 100 μg/m3 as the maximum average over an 8-hour period.[29] The EPA standard for ozone concentration is 0.07 ppm average over an 8-hour period.[70]
Occupants in buildings can be exposed to fungal spores, cell fragments, or mycotoxins which can arise from a host of means, but there are two common classes: (a) excess moisture induced growth of mold colonies and (b) natural substances released into the air such as animal dander and plant pollen.[71]
While mold growth is associated with high moisture levels,[72] it is likely to grow when a combination of favorable conditions arises. As well as high moisture levels, these conditions include suitable temperatures, pH and nutrient sources.[73] Mold grows primarily on surfaces, and it reproduces by releasing spores, which can travel and settle in different locations. When these spores experience appropriate conditions, they can germinate and lead to mycelium growth.[74] Different mold species favor different environmental conditions to germinate and grow, some being more hydrophilic (growing at higher levels of relative humidity) and other more xerophilic (growing at levels of relative humidity as low as 75–80%).[74][75]
Mold growth can be inhibited by keeping surfaces at conditions that are further from condensation, with relative humidity levels below 75%. This usually translates to a relative humidity of indoor air below 60%, in agreement with the guidelines for thermal comfort that recommend a relative humidity between 40 and 60 %. Moisture buildup in buildings may arise from water penetrating areas of the building envelope or fabric, from plumbing leaks, rainwater or groundwater penetration, or from condensation due to improper ventilation, insufficient heating or poor thermal quality of the building envelope.[76] Even something as simple as drying clothes indoors on radiators can increase the risk of mold growth, if the humidity produced is not able to escape the building via ventilation.[77]
Mold predominantly affects the airways and lungs. Known effects of mold on health include asthma development and exacerbation,[78] with children and elderly at greater risk of more severe health impacts.[79] Infants in homes with mold have a much greater risk of developing asthma and allergic rhinitis.[80][71] More than half of adult workers in moldy or humid buildings suffer from nasal or sinus symptoms due to mold exposure.[71] Some varieties of mold contain toxic compounds (mycotoxins). However, exposure to hazardous levels of mycotoxin via inhalation is not possible in most cases, as toxins are produced by the fungal body and are not at significant levels in the released spores.
Legionnaires' disease is caused by a waterborne bacterium Legionella that grows best in slow-moving or still, warm water. The primary route of exposure is through the creation of an aerosol effect, most commonly from evaporative cooling towers or showerheads. A common source of Legionella in commercial buildings is from poorly placed or maintained evaporative cooling towers, which often release water in an aerosol which may enter nearby ventilation intakes. Outbreaks in medical facilities and nursing homes, where patients are immuno-suppressed and immuno-weak, are the most commonly reported cases of Legionellosis. More than one case has involved outdoor fountains at public attractions. The presence of Legionella in commercial building water supplies is highly under-reported, as healthy people require heavy exposure to acquire infection.
Legionella testing typically involves collecting water samples and surface swabs from evaporative cooling basins, shower heads, faucets/taps, and other locations where warm water collects. The samples are then cultured and colony forming units (cfu) of Legionella are quantified as cfu/liter.
Legionella is a parasite of protozoans such as amoeba, and thus requires conditions suitable for both organisms. The bacterium forms a biofilm which is resistant to chemical and antimicrobial treatments, including chlorine. Remediation for Legionella outbreaks in commercial buildings vary, but often include very hot water flushes (160 °F (71 °C)), sterilisation of standing water in evaporative cooling basins, replacement of shower heads, and, in some cases, flushes of heavy metal salts. Preventive measures include adjusting normal hot water levels to allow for 120 °F (49 °C) at the tap, evaluating facility design layout, removing faucet aerators, and periodic testing in suspect areas.
There are many bacteria of health significance found in indoor air and on indoor surfaces. The role of microbes in the indoor environment is increasingly studied using modern gene-based analysis of environmental samples. Currently, efforts are under way to link microbial ecologists and indoor air scientists to forge new methods for analysis and to better interpret the results.[81]
A large fraction of the bacteria found in indoor air and dust are shed from humans. Among the most important bacteria known to occur in indoor air are Mycobacterium tuberculosis, Staphylococcus aureus, Streptococcus pneumoniae.[citation needed]
Viruses can also be a concern for indoor air quality. During the 2002–2004 SARS outbreak, virus-laden aerosols were found to have seeped into bathrooms from the bathroom floor drains, exacerbated by the draw of bathroom exhaust fans, resulting in the rapid spread of SARS in Amoy Gardens in Hong Kong.[82][83] Elsewhere in Hong Kong, SARS CoV RNA was found on the carpet and in the air intake vents of the Metropole Hotel, which showed that secondary environmental contamination could generate infectious aerosols and resulted in superspreading events.[84]
Humans are the main indoor source of carbon dioxide (CO2) in most buildings. Indoor CO2 levels are an indicator of the adequacy of outdoor air ventilation relative to indoor occupant density and metabolic activity.
Indoor CO2 levels above 500 ppm can lead to higher blood pressure and heart rate, and increased peripheral blood circulation.[85] With CO2 concentrations above 1000 ppm cognitive performance might be affected, especially when doing complex tasks, making decision making and problem solving slower but not less accurate.[86][87] However, evidence on the health effects of CO2 at lower concentrations is conflicting and it is difficult to link CO2 to health impacts at exposures below 5000 ppm – reported health outcomes may be due to the presence of human bioeffluents, and other indoor air pollutants related to inadequate ventilation.[88]
Indoor carbon dioxide concentrations can be used to evaluate the quality of a room or a building's ventilation.[89] To eliminate most complaints caused by CO2, the total indoor CO2 level should be reduced to a difference of no greater than 700 ppm above outdoor levels.[90] The National Institute for Occupational Safety and Health (NIOSH) considers that indoor air concentrations of carbon dioxide that exceed 1000 ppm are a marker suggesting inadequate ventilation.[91] The UK standards for schools say that carbon dioxide levels of 800 ppm or lower indicate that the room is well-ventilated.[92] Regulations and standards from around the world show that CO2 levels below 1000 ppm represent good IAQ, between 1000 and 1500 ppm represent moderate IAQ and greater than 1500 ppm represent poor IAQ.[88]
Carbon dioxide concentrations in closed or confined rooms can increase to 1,000 ppm within 45 minutes of enclosure. For example, in a 3.5-by-4-metre (11 ft × 13 ft) sized office, atmospheric carbon dioxide increased from 500 ppm to over 1,000 ppm within 45 minutes of ventilation cessation and closure of windows and doors.[93]
Radon is an invisible, radioactive atomic gas that results from the radioactive decay of radium, which may be found in rock formations beneath buildings or in certain building materials themselves.
Radon is probably the most pervasive serious hazard for indoor air in the United States and Europe. It is a major cause of lung cancer, responsible for 3–14% of cases in countries, leading to tens of thousands of deaths.[94]
Radon gas enters buildings as a soil gas. As it is a heavy gas it will tend to accumulate at the lowest level. Radon may also be introduced into a building through drinking water particularly from bathroom showers. Building materials can be a rare source of radon, but little testing is carried out for stone, rock or tile products brought into building sites; radon accumulation is greatest for well insulated homes.[95] There are simple do-it-yourself kits for radon gas testing, but a licensed professional can also check homes.
The half-life for radon is 3.8 days, indicating that once the source is removed, the hazard will be greatly reduced within a few weeks. Radon mitigation methods include sealing concrete slab floors, basement foundations, water drainage systems, or by increasing ventilation.[96] They are usually cost effective and can greatly reduce or even eliminate the contamination and the associated health risks.[citation needed]
Radon is measured in picocuries per liter of air (pCi/L) or becquerel per cubic meter (Bq m-3). Both are measurements of radioactivity. The World Health Organization (WHO) sets the ideal indoor radon levels at 100 Bq/m-3.[97] In the United States, it is recommend to fix homes with radon levels at or above 4 pCi/L. At the same time it is also recommends that people think about fixing their homes for radon levels between 2 pCi/L and 4 pCi/L.[98] In the United Kingdom the ideal is presence of radon indoors is 100 Bq/m-3. Action needs to be taken in homes with 200 Bq/m−3 or more.[99]
Interactive maps of radon affected areas are available for various regions and countries of the world.[100][101][102]
Indoor air quality is linked inextricably to outdoor air quality. The Intergovernmental Panel on Climate Change (IPCC) has varying scenarios that predict how the climate will change in the future.[103] Climate change can affect indoor air quality by increasing the level of outdoor air pollutants such as ozone and particulate matter, for example through emissions from wildfires caused by extreme heat and drought.[104][105] Numerous predictions for how indoor air pollutants will change have been made,[106][107][108][109] and models have attempted to predict how the forecasted IPCC scenarios will vary indoor air quality and indoor comfort parameters such as humidity and temperature.[110]
The net-zero challenge requires significant changes in the performance of both new and retrofitted buildings. However, increased energy efficient housing will trap pollutants inside, whether produced indoors or outdoors, and lead to an increase in human exposure.[111][112]
For occupational exposure, there are standards, which cover a wide range of chemicals, and applied to healthy adults who are exposed over time at workplaces (usually industrial environments).These are published by organisations such as Occupational Safety and Health Administration (OSHA), the National Institute for Occupational Safety and Health (NIOSH), the UK Health and Safety Executive (HSE).
There is no consensus globally about indoor air quality standards, or health-based guidelines. However, there are regulations from some individual countries and from health organisations. For example, the World Health Organization (WHO) has published health-based global air quality guidelines for the general population that are applicable both to outdoor and indoor air,[29] as well as the WHO IAQ guidelines for selected compounds,[113] whereas the UK Health Security Agency published IAQ guidelines for selected VOCs.[114] The Scientific and Technical Committee (STC34) of the International Society of Indoor Air Quality and Climate (ISIAQ) created an open database that collects indoor environmental quality guidelines worldwide.[115] The database is focused on indoor air quality (IAQ), but is currently extended to include standards, regulations, and guidelines related to ventilation, comfort, acoustics, and lighting.[116][117]
Since indoor air pollutants can adversely affect human health, it is important to have real-time indoor air quality assessment/monitoring system that can help not only in the improvement of indoor air quality but also help in detection of leaks, spills in a work environment and boost energy efficiency of buildings by providing real-time feedback to the heating, ventilation, and air conditioning (HVAC) system(s).[118] Additionally, there have been enough studies that highlight the correlation between poor indoor air quality and loss of performance and productivity of workers in an office setting.[119]
Combining the Internet of Things (IoT) technology with real-time IAQ monitoring systems has tremendously gained momentum and popularity as interventions can be done based on the real-time sensor data and thus help in the IAQ improvement.[120]
This section needs expansion. You can help by adding to it. (November 2023)
|
Indoor air quality can be addressed, achieved or maintained during the design of new buildings or as mitigating measures in existing buildings. A hierarchy of measures has been proposed by the Institute of Air Quality Management. It emphasises removing pollutant sources, reducing emissions from any remaining sources, disrupting pathways between sources and the people exposed, protecting people from exposure to pollutants, and removing people from areas with poor air quality.[121]
A report assisted by the Institute for Occupational Safety and Health of the German Social Accident Insurance can support in the systematic investigation of individual health problems arising at indoor workplaces, and in the identification of practical solutions.[122]
![]() |
This section is empty. You can help by adding to it. (September 2024)
|
This section needs additional citations for verification. (November 2019)
|
Environmentally sustainable design concepts include aspects of commercial and residential heating, ventilation and air-conditioning (HVAC) technologies. Among several considerations, one of the topics attended to is the issue of indoor air quality throughout the design and construction stages of a building's life.[citation needed]
One technique to reduce energy consumption while maintaining adequate air quality, is demand-controlled ventilation. Instead of setting throughput at a fixed air replacement rate, carbon dioxide sensors are used to control the rate dynamically, based on the emissions of actual building occupants.[citation needed]
One way of quantitatively ensuring the health of indoor air is by the frequency of effective turnover of interior air by replacement with outside air. In the UK, for example, classrooms are required to have 2.5 outdoor air changes per hour. In halls, gym, dining, and physiotherapy spaces, the ventilation should be sufficient to limit carbon dioxide to 1,500 ppm. In the US, ventilation in classrooms is based on the amount of outdoor air per occupant plus the amount of outdoor air per unit of floor area, not air changes per hour. Since carbon dioxide indoors comes from occupants and outdoor air, the adequacy of ventilation per occupant is indicated by the concentration indoors minus the concentration outdoors. The value of 615 ppm above the outdoor concentration indicates approximately 15 cubic feet per minute of outdoor air per adult occupant doing sedentary office work where outdoor air contains over 400 ppm[123] (global average as of 2023). In classrooms, the requirements in the ASHRAE standard 62.1, Ventilation for Acceptable Indoor Air Quality, would typically result in about 3 air changes per hour, depending on the occupant density. As the occupants are not the only source of pollutants, outdoor air ventilation may need to be higher when unusual or strong sources of pollution exist indoors.
When outdoor air is polluted, bringing in more outdoor air can actually worsen the overall quality of the indoor air and exacerbate some occupant symptoms related to outdoor air pollution. Generally, outdoor country air is better than indoor city air.[citation needed]
The use of air filters can trap some of the air pollutants. Portable room air cleaners with HEPA filters can be used if ventilation is poor or outside air has high level of PM 2.5.[122] Air filters are used to reduce the amount of dust that reaches the wet coils.[citation needed] Dust can serve as food to grow molds on the wet coils and ducts and can reduce the efficiency of the coils.[citation needed]
The use of trickle vents on windows is also valuable to maintain constant ventilation. They can help prevent mold and allergen build up in the home or workplace. They can also reduce the spread of some respiratory infections.[124]
Moisture management and humidity control requires operating HVAC systems as designed. Moisture management and humidity control may conflict with efforts to conserve energy. For example, moisture management and humidity control requires systems to be set to supply make-up air at lower temperatures (design levels), instead of the higher temperatures sometimes used to conserve energy in cooling-dominated climate conditions. However, for most of the US and many parts of Europe and Japan, during the majority of hours of the year, outdoor air temperatures are cool enough that the air does not need further cooling to provide thermal comfort indoors.[citation needed] However, high humidity outdoors creates the need for careful attention to humidity levels indoors. High humidity give rise to mold growth and moisture indoors is associated with a higher prevalence of occupant respiratory problems.[citation needed]
The "dew point temperature" is an absolute measure of the moisture in air. Some facilities are being designed with dew points in the lower 50s °F, and some in the upper and lower 40s °F.[citation needed] Some facilities are being designed using desiccant wheels with gas-fired heaters to dry out the wheel enough to get the required dew points.[citation needed] On those systems, after the moisture is removed from the make-up air, a cooling coil is used to lower the temperature to the desired level.[citation needed]
Commercial buildings, and sometimes residential, are often kept under slightly positive air pressure relative to the outdoors to reduce infiltration. Limiting infiltration helps with moisture management and humidity control.
Dilution of indoor pollutants with outdoor air is effective to the extent that outdoor air is free of harmful pollutants. Ozone in outdoor air occurs indoors at reduced concentrations because ozone is highly reactive with many chemicals found indoors. The products of the reactions between ozone and many common indoor pollutants include organic compounds that may be more odorous, irritating, or toxic than those from which they are formed. These products of ozone chemistry include formaldehyde, higher molecular weight aldehydes, acidic aerosols, and fine and ultrafine particles, among others. The higher the outdoor ventilation rate, the higher the indoor ozone concentration and the more likely the reactions will occur, but even at low levels, the reactions will take place. This suggests that ozone should be removed from ventilation air, especially in areas where outdoor ozone levels are frequently high.
Houseplants together with the medium in which they are grown can reduce components of indoor air pollution, particularly volatile organic compounds (VOC) such as benzene, toluene, and xylene. Plants remove CO2 and release oxygen and water, although the quantitative impact for house plants is small. The interest in using potted plants for removing VOCs was sparked by a 1989 NASA study conducted in sealed chambers designed to replicate the environment on space stations. However, these results suffered from poor replication[125] and are not applicable to typical buildings, where outdoor-to-indoor air exchange already removes VOCs at a rate that could only be matched by the placement of 10–1000 plants/m2 of a building's floor space.[126]
Plants also appear to reduce airborne microbes and molds, and to increase humidity.[127] However, the increased humidity can itself lead to increased levels of mold and even VOCs.[128]
Since extremely high humidity is associated with increased mold growth, allergic responses, and respiratory responses, the presence of additional moisture from houseplants may not be desirable in all indoor settings if watering is done inappropriately.[129]
The topic of IAQ has become popular due to the greater awareness of health problems caused by mold and triggers to asthma and allergies.
In the US, the Environmental Protection Agency (EPA) has developed an "IAQ Tools for Schools" program to help improve the indoor environmental conditions in educational institutions. The National Institute for Occupational Safety and Health conducts Health Hazard Evaluations (HHEs) in workplaces at the request of employees, authorized representative of employees, or employers, to determine whether any substance normally found in the place of employment has potentially toxic effects, including indoor air quality.[130]
A variety of scientists work in the field of indoor air quality, including chemists, physicists, mechanical engineers, biologists, bacteriologists, epidemiologists, and computer scientists. Some of these professionals are certified by organizations such as the American Industrial Hygiene Association, the American Indoor Air Quality Council and the Indoor Environmental Air Quality Council.
In the UK, under the Department for Environment Food and Rural Affairs, the Air Quality Expert Group considers current knowledge on indoor air quality and provides advice to government and devolved administration ministers.[131]
At the international level, the International Society of Indoor Air Quality and Climate (ISIAQ), formed in 1991, organizes two major conferences, the Indoor Air and the Healthy Buildings series.[132]
According to the Global Burden of Disease study 1.6 million people died prematurely in 2017 as a result of indoor air pollution ... But it's worth noting that the WHO publishes a substantially larger number of indoor air pollution deaths..
Burning of natural gas not only produces a variety of gases such as sulfur oxides, mercury compounds, and particulate matter but also leads to the production of nitrogen oxides, primarily nitrogen dioxide...The burning of biomass fuel or any other fossil fuel increases the concentration of black carbon in the air
MPs have been found in water and soil, and recent research is exposing the vast amount of them in ambient and indoor air.
environmental contamination with SARS CoV RNA was identified on the carpet in front of the index case-patient's room and 3 nearby rooms (and on their door frames but not inside the rooms) and in the air intake vents near the centrally located elevators ... secondary infections occurred not in guest rooms but in the common areas of the ninth floor, such as the corridor or elevator hall. These areas could have been contaminated through body fluids (e.g., vomitus, expectorated sputum), respiratory droplets, or suspended small-particle aerosols generated by the index case-patient; other guests were then infected by fomites or aerosols while passing through these same areas. Efficient spread of SARS CoV through small-particle aerosols was observed in several superspreading events in health care settings, during an airplane flight, and in an apartment complex (12–14,16–19). This process of environmental contamination that generated infectious aerosols likely best explains the pattern of disease transmission at the Hotel Metropole.
cite journal
: CS1 maint: numeric names: authors list (link)